Distal-to-proximal delay for ablation of premature ventricular contractions.
Clementy, Nicolas; Ancedy, Yann; Bisson, Arnaud; Andre, Clémentine; Pierre, Bertrand; Fauchier, Laurent; Babuty, Dominique.
Afiliação
  • Clementy N; Cardiology Department, University of Tours, Tours, France.
  • Ancedy Y; Cardiology Department, University of Tours, Tours, France.
  • Bisson A; Cardiology Department, University of Tours, Tours, France.
  • Andre C; Cardiology Department, University of Tours, Tours, France.
  • Pierre B; Cardiology Department, University of Tours, Tours, France.
  • Fauchier L; Cardiology Department, University of Tours, Tours, France.
  • Babuty D; Cardiology Department, University of Tours, Tours, France.
J Cardiovasc Electrophysiol ; 30(2): 205-211, 2019 02.
Article em En | MEDLINE | ID: mdl-30516303
ABSTRACT

INTRODUCTION:

Ablation of premature ventricular contractions (PVCs) has emerged as a safe and effective treatment in patients experiencing a high PVCs burden. Mapping of PVCs origin may sometimes be challenging. We sought to evaluate the accuracy of a new electrophysiological criterion, the distal-to-proximal (DP) delay, at localizing the optimal site for ablation of ventricular ectopic foci. METHODS AND

RESULTS:

Consecutive patients with ablation attempts of symptomatic PVCs were included. Prematurity and DP delay-that is, the time duration between the onset of ablation catheter distal bipolar electrogram and the onset of proximal bipolar electrogram-were measured at successful and unsuccessful ablation sites by three blinded experienced electrophysiologists. Mean DP delay at effective ablation sites (N = 30) was significantly higher than at ineffective sites ( N = 55) (23 ± 9 vs 11 ± 8 milliseconds; P < 0.0001). DP delay had good-to-excellent interrater reliability. A DP delay greater than or equal to 15 milliseconds had the highest accuracy at predicting a successful ablation site (sensitivity 0.97, the area under receiver operating characteristic curve 0.87; P < 0.0001).

CONCLUSION:

DP delay is an additional, simple, and effective electrophysiological parameter to accurately localize PVCs foci.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Complexos Ventriculares Prematuros / Técnicas Eletrofisiológicas Cardíacas / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Complexos Ventriculares Prematuros / Técnicas Eletrofisiológicas Cardíacas / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: França