Your browser doesn't support javascript.
loading
[Temporary Bypass with 5-Fr Catheter for Reconstruction of Superior Vena Cava].
Kyobu Geka ; 71(13): 1077-1080, 2018 12.
Article em Ja | MEDLINE | ID: mdl-30587745
ABSTRACT
A 21-year-old man was referred to our hospital because of an abnormal shadow on a routine chest radiogram. Enhanced computed tomography showed an 83×74 mm mass in the anterior mediastinum, with invasion of the superior vena cava (SVC). Surgical resection with sternotomy was performed. Intraoperative temporary bypass grafting with a 5-Fr catheter was performed between the right brachiocephalic vein and right atrium. The mediastinal tumor was resected with the SVC, and SVC reconstruction with a 16 mm expanded polytetrafluoroethylene graft was performed. The bypass stabilized intraoperative vital signs and enabled safe completion of the operation. The pathological diagnosis was seminoma. SVC replacement combined with temporary bypass using a small diameter catheter is technically feasible and safe.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Cava Superior / Seminoma / Neoplasias do Mediastino Limite: Adult / Humans / Male Idioma: Ja Revista: Kyobu Geka Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão
Buscar no Google