Your browser doesn't support javascript.
loading
Inter-laboratory proficiency results of blood alcohol determinations at clinical and forensic laboratories in Italy.
Zamengo, Luca; Tedeschi, Gianpaola; Frison, Giampietro; Griffoni, Carlo; Ponzin, Diego; Jones, Alan Wayne.
Afiliação
  • Zamengo L; Laboratory of Environmental Hygiene and Forensic Toxicology, DMPO Department, AULSS 3, Venice, Italy. Electronic address: luca.zamengo@aulss3.veneto.it.
  • Tedeschi G; Laboratory of Environmental Hygiene and Forensic Toxicology, DMPO Department, AULSS 3, Venice, Italy.
  • Frison G; Laboratory of Environmental Hygiene and Forensic Toxicology, DMPO Department, AULSS 3, Venice, Italy.
  • Griffoni C; Veneto Eye Bank Foundation, Venice, Italy.
  • Ponzin D; Veneto Eye Bank Foundation, Venice, Italy.
  • Jones AW; Department of Clinical Pharmacology, Linköping University, Linköping, Sweden.
Forensic Sci Int ; 295: 213-218, 2019 Feb.
Article em En | MEDLINE | ID: mdl-30611561
ABSTRACT

BACKGROUND:

Inter-laboratory proficiency schemes are widely used to control the performance of clinical and forensic toxicology laboratories. In 2016 the Laboratory of Environmental Hygiene and Forensic Toxicology - Venice (Italy) initiated an inter-laboratory proficiency test of blood-alcohol analysis. The number of participating laboratories gradually increased from 26 to 36. Furthermore, a few clinical laboratories were included if gas chromatographic (GC) methods were used for blood alcohol analysis. PROCEDURE Whole blood was obtained from the Blood Transfusion Centre of the Venice Hospital and a mixture of sodium fluoride and potassium oxalate was added as a preservative and anticoagulant, respectively. Aliquots of the blood were spiked with certified pure ethanol to obtain target blood-alcohol concentrations (BACs) ranging from 0 to 5.0g/L. Two blood samples (4mL each) were included in each shipment to the participating laboratories. The laboratories were asked to provide information about number of replicate BAC determinations they made, the types of ethanol reference standards used, and inherent measurement uncertainty. The aim of the testing was to obtain a mean consensus value for the target BAC and to assess inter-laboratory imprecision. All procedures for registration and submission of results were done on-line. A confidential report and statistical evaluations were returned to the participants one week later. ANALYTICAL

METHODS:

All participants used head-space GC (HS-GC) for the analysis of ethanol in blood. More than 85% of participants used HS-GC with flame-ionization detection, whereas the others used mass spectrometry (MS) as a detector. More than 40% of the participating laboratories kept the blood samples frozen (-20°C) prior to analysis, whereas the others used refrigeration (+4°C). The preliminary validation tests showed that there were no statistically significant differences between BAC in frozen or refrigerated samples for a period of 20 days. RESULTS AND

CONCLUSION:

The statistical evaluation of results was done using an iterative procedure known as Algorithm A (ISO 135282015, C.3.1). This provides robust estimates for mean and standard deviation between laboratories and these were used as consensus values. More than 85% of participants provided satisfactory results (z-score <1) and 94% of laboratories were within z-score <2, based on five control samples. When a blood sample without any alcohol (blank) was sent for analysis, laboratories reported this as zero, 0.00g/L, below limit of detection (LOD) or not detected. Some type of consensus should be reached for reporting blank samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Detecção do Abuso de Substâncias / Concentração Alcoólica no Sangue / Laboratórios Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Forensic Sci Int Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Detecção do Abuso de Substâncias / Concentração Alcoólica no Sangue / Laboratórios Tipo de estudo: Guideline Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Forensic Sci Int Ano de publicação: 2019 Tipo de documento: Article