Your browser doesn't support javascript.
loading
Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study.
You, Sun Kyoung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One; Lee, So Mi; Cho, Hyun-Hae.
Afiliação
  • You SK; Department of Radiology, Chungnam National University College of Medicine, Daejeon, Republic of Korea.
  • Choi YH; Department of Radiology, Chungnam National University Hospital, Daejeon, Republic of Korea.
  • Cheon JE; Department of Radiology, Seoul National University Children's Hospital, Seoul, Republic of Korea. iater@snu.ac.kr.
  • Kim WS; Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea. iater@snu.ac.kr.
  • Kim IO; Department of Radiology, Seoul National University Children's Hospital, Seoul, Republic of Korea.
  • Lee SM; Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Cho HH; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
Abdom Radiol (NY) ; 44(5): 1928-1935, 2019 05.
Article em En | MEDLINE | ID: mdl-30683980
ABSTRACT

PURPOSE:

To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. MATERIALS AND

METHODS:

The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18) tube voltage, 70 kVp; and iodine concentration, 250 mgI/mL versus Conventional protocol (Group B, n = 13) tube voltage, 80-100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded.

RESULTS:

The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59-0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively).

CONCLUSION:

The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Abdominal / Tomografia Computadorizada por Raios X / Meios de Contraste Tipo de estudo: Observational_studies / Qualitative_research Limite: Child / Female / Humans / Male Idioma: En Revista: Abdom Radiol (NY) Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiografia Abdominal / Tomografia Computadorizada por Raios X / Meios de Contraste Tipo de estudo: Observational_studies / Qualitative_research Limite: Child / Female / Humans / Male Idioma: En Revista: Abdom Radiol (NY) Ano de publicação: 2019 Tipo de documento: Article