Wirelessly Controlled Implantable System for On-demand and Pulsatile Insulin Administration.
Lee, Seung Ho; Ahn, Joong Woo; Cho, Yong Chan; Kim, Se-Na; Lee, Cheol; Ku, Gi Won; Bin Choy, Young; Kim, Hee Chan.
Afiliação
  • Lee SH; Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul, 03080, Republic of Korea.
  • Ahn JW; Seoul National University Hospital Biomedical Research Institute, Seoul, 03082, South Korea.
  • Cho YC; Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, 08826, Republic of Korea.
  • Kim SN; Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, 08826, Republic of Korea.
  • Lee C; Department of Pathology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea.
  • Ku GW; Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea.
  • Bin Choy Y; Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul, 03080, Republic of Korea. ybchoy@snu.ac.kr.
  • Kim HC; Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, 08826, Republic of Korea. ybchoy@snu.ac.kr.
Sci Rep ; 9(1): 5009, 2019 03 21.
Article em En | MEDLINE | ID: mdl-30899066
ABSTRACT
We propose a wirelessly controlled implantable system for on-demand and pulsatile insulin delivery with a more convenient and safer strategy than currently available strategies. The system is a combined entity of a magnetically driven pump (i.e., an MDP), external control device (i.e., an ECD) and mobile app. The MDP for implantation consists of a plunger, barrel and drug reservoir, where an accurate amount of insulin can be infused in a pulsatile manner only at the time when a magnetic force is applied to actuate the plunger in the barrel. The ECD at the outside body can modulate the MDP actuation with an electromagnet and its control circuit, and this modulation can be wirelessly controlled by the mobile app. As a safety feature, the mobile app is programmed to pre-set the restrictions for the insulin dose and administration schedule to avoid overdose. The system is shown to infuse insulin in a highly reproducible manner, but it does not allow for insulin infusion when the pre-set restrictions are violated. When tested with diabetic rats, the profiles of insulin plasma concentration and blood glucose level are similar to those of animals treated with a subcutaneous injection of the same dose of insulin.