Your browser doesn't support javascript.
loading
Developing pediatric three-dimensional upper airway normative values using fixed and interactive thresholds.
Masoud, Ahmed I; Alwadei, Farhan H; Alwadei, Abdurahman H; Lin, Edward Y; Viana, Maria Grace Costa; Kusnoto, Budi; Evans, Carla A.
Afiliação
  • Masoud AI; Department of Orthodontics, Faculty of Dentistry, King Abdulaziz University, PO Box 80209, Jeddah, 21589, Saudi Arabia. aemasoud@kau.edu.sa.
  • Alwadei FH; University of Illinois at Chicago, Chicago, IL, USA. aemasoud@kau.edu.sa.
  • Alwadei AH; Department of Preventive Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al Kharj, Saudi Arabia.
  • Lin EY; Department of Pediatric Dentistry and Orthodontics, Faculty of Dentistry, King Saud University, Riyadh, Saudi Arabia.
  • Viana MGC; Orthodontic Specialists of Green Bay, Green Bay, WI, USA.
  • Kusnoto B; Department of Orthodontics, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA.
  • Evans CA; Department of Orthodontics, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA.
Oral Radiol ; 36(1): 89-99, 2020 01.
Article em En | MEDLINE | ID: mdl-30963481
ABSTRACT

OBJECTIVE:

To develop and compare pediatric upper airway three-dimensional normative values using the two most commonly used cone beam computed tomography (CBCT) software Invivo5 (fixed threshold) and Dolphin 3D (interactive threshold). STUDY

DESIGN:

Out of 3738 CBCT scans, scans of 81 pediatric patients were utilized after applying strict exclusion criteria. The sample was grouped into two age groups (7-11 and 12-17 years). Intra-class correlation coefficient was used to test intra-rater and inter-rater reliability and showed coefficients greater than 0.9 indicating good reliability of the methods used.

RESULTS:

Paired t tests showed that volumetric and area measurements obtained using Dolphin 3D were significantly larger than those obtained using Invivo5 (p < 0.05). The mean minimal cross-sectional areas (MCSA) for Dolphin 3D were 151 mm2 and 177 mm2 for age groups 1 and 2, respectively. The mean MCSA values for Invivo5 for age groups 1 and 2 were 120 mm2 and 145 mm2, respectively.

CONCLUSION:

Pediatric upper airway volumetric, area, and linear measurements were reported after applying strict exclusion criteria including a validated sleep questionnaire. Our goal is that clinicians utilize the proposed-here normative values for screening and assist in the timely diagnosis and management of pediatric sleep apnea.