Your browser doesn't support javascript.
loading
A retrospective study of endobronchial ultrasound transbronchial needle aspiration versus conventional transbronchial needle aspiration in diagnosis/staging of hilar/mediastinal lymph node in lung cancer: Which role in clinical practice?
Conte, Sergio C; Spagnol, Giulia; Biolo, Marco; Confalonieri, Marco.
Afiliação
  • Conte SC; Pulmonary Diseases Unit, Department of Medicine, ULSS2 Marca Trevigiana, Hospital of Vittorio Veneto. sergio.conte@aulss2.veneto.it.
Monaldi Arch Chest Dis ; 89(1)2019 Apr 17.
Article em En | MEDLINE | ID: mdl-30996353
The conventional-trans bronchial needle aspiration (c-TBNA) has been the first procedure for sampling hilar/mediastinal lymph node for the diagnosis/staging of lung cancer. In the last decade the endobronchial ultrasound trans bronchial needle aspiration (EBUS-TBNA) was introduced in clinical practice and became the first-choice exam in diagnosis and staging of lung cancer. The aim of this study was to compare the diagnostic accuracy (DA), sensitivity and adequacy of c-TBNA and EBUS-TBNA. It was a retrospective and observational multicenter study. The first endpoint was diagnostic accuracy of EBUS-TBNA versus c-TBNA. The secondary end-points were sensitivity and adequacy. Two hundred and nine consecutive patients underwent the procedure, 99 EBUS-TBNA and 110 c-TBNA. When lymph nodes with short axis <2 cm the diagnostic accuracy for correct diagnosis was 94.2% in EBUS-TBNA group and 89.7% in c-TBNA group (p=0.01); the sample adequacy was 70.3% and 42%, respectively (p=0.01); the sensitivity was 93% (95% CI, 82-98%) and 86.4% (95% CI, 67.6-95.6%), respectively (p=0.002). In lymph nodes with short axis ≥2 cm the diagnostic accuracy was 95.7% in EBUS-TBNA group and 93% in c-TBNA group (p=0.939); the sample adequacy was 68.7% and 68.3%, respectively (p=0.889); the sensitivity was 95.1% (95% CI, 83-99%) and 92.1%, respectively (95% CI, 78.7-97.7%) (p=0.898). The EBUS-TBNA in patients with lymph nodes size <2 cm presented a statistically significant difference in the DA, adequacy and sensitivity compared to c-TBNA procedure, while there were no significant differences in the DA, adequacy and sensitivity between EBUS-TBNA and c-TBNA in patients with lymph node size ≥2 cm. The results of our study indicated that the EBUS-TBNA should be the first-choice procedure for the diagnosis/staging in lung cancer patients with lymph node size <2 cm. In patients with lymph node size ≥2 cm, instead, both procedures can be used for the diagnosis/staging of lung cancer.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncoscopia / Ultrassonografia / Biópsia por Agulha Fina / Linfonodos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Monaldi Arch Chest Dis Ano de publicação: 2019 Tipo de documento: Article País de publicação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncoscopia / Ultrassonografia / Biópsia por Agulha Fina / Linfonodos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Monaldi Arch Chest Dis Ano de publicação: 2019 Tipo de documento: Article País de publicação: Itália