Your browser doesn't support javascript.
loading
Accurate assessment of LV function using the first automated 2D-border detection algorithm for small animals - evaluation and application to models of LV dysfunction.
Grune, Jana; Ritter, Daniel; Kräker, Kristin; Pappritz, Kathleen; Beyhoff, Niklas; Schütte, Till; Ott, Christiane; John, Cathleen; van Linthout, Sophie; Tschöpe, Carsten; Dechend, Ralf; Muller, Dominik N; Haase, Nadine; Grune, Tilman; Kintscher, Ulrich; Kuebler, Wolfgang M.
Afiliação
  • Grune J; Institute of Physiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
  • Ritter D; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Kräker K; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Pappritz K; Institute of Pharmacology, Center for Cardiovascular Research, Charité - Universitaetsmedizin Berlin, Hessische Straße 3-4, 10115, Berlin, Germany.
  • Beyhoff N; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Schütte T; Experimental and Clinical Research Center, a joint cooperation of Max-Delbrück Center for Molecular Medicine and Charité - Universitätsmedizin Berlin, 13125, Berlin, Germany.
  • Ott C; Berlin Institute of Health (BIH), Berlin, Germany.
  • John C; Max-Delbrück Center for Molecular Medicine, 13125, Berlin, Germany.
  • van Linthout S; Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and BIH, Berlin, Germany.
  • Tschöpe C; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Dechend R; Berlin - Brandenburger Center for Regenerative Therapies (BCRT), Charité - Universitätsmedizin Berlin, Campus Virchow Klinikum (CVK), Berlin, Germany.
  • Muller DN; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Haase N; Institute of Pharmacology, Center for Cardiovascular Research, Charité - Universitaetsmedizin Berlin, Hessische Straße 3-4, 10115, Berlin, Germany.
  • Grune T; German Centre for Cardiovascular Research (DZHK), partner site Berlin, 10117, Berlin, Germany.
  • Kintscher U; Institute of Pharmacology, Center for Cardiovascular Research, Charité - Universitaetsmedizin Berlin, Hessische Straße 3-4, 10115, Berlin, Germany.
  • Kuebler WM; Berlin Institute of Health (BIH), Berlin, Germany.
Cardiovasc Ultrasound ; 17(1): 7, 2019 Apr 22.
Article em En | MEDLINE | ID: mdl-31010431
ABSTRACT
Echocardiography is the most commonly applied technique for non-invasive assessment of cardiac function in small animals. Manual tracing of endocardial borders is time consuming and varies with operator experience. Therefore, we aimed to evaluate a novel automated two-dimensional software algorithm (Auto2DE) for small animals and compare it to the standard use of manual 2D-echocardiographic assessment (2DE). We hypothesized that novel Auto2DE will provide rapid and robust data sets, which are in agreement with manually assessed data of animals.2DE and Auto2DE were carried out using a high-resolution imaging-system for small animals. First, validation cohorts of mouse and rat cine loops were used to compare Auto2DE against 2DE. These data were stratified for image quality by a blinded expert in small animal imaging. Second, we evaluated 2DE and Auto2DE in four mouse models and four rat models with different cardiac pathologies.Automated assessment of LV function by 2DE was faster than conventional 2DE analysis and independent of operator experience levels. The accuracy of Auto2DE-assessed data in healthy mice was dependent on cine loop quality, with excellent agreement between Auto2DE and 2DE in cine loops with adequate quality. Auto2DE allowed for valid detection of impaired cardiac function in animal models with pronounced cardiac phenotypes, but yielded poor performance in diabetic animal models independent of image quality.Auto2DE represents a novel automated analysis tool for rapid assessment of LV function, which is suitable for data acquisition in studies with good and very good echocardiographic image quality, but presents systematic problems in specific pathologies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Ecocardiografia / Função Ventricular Esquerda / Disfunção Ventricular Esquerda / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Ecocardiografia / Função Ventricular Esquerda / Disfunção Ventricular Esquerda / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Cardiovasc Ultrasound Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha