Your browser doesn't support javascript.
loading
Acceleration-selective arterial spin labeling MR angiography for visualization of brain arteriovenous malformations.
Togao, Osamu; Hiwatashi, Akio; Yamashita, Koji; Momosaka, Daichi; Obara, Makoto; Nishimura, Ataru; Arimura, Koichi; Hata, Nobuhiro; Iihara, Koji; Van Cauteren, Marc; Honda, Hiroshi.
Afiliação
  • Togao O; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan. togao@radiol.med.kyushu-u.ac.jp.
  • Hiwatashi A; Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Yamashita K; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Momosaka D; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Obara M; Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan.
  • Nishimura A; Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Arimura K; Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Hata N; Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Iihara K; Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
  • Van Cauteren M; Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan.
  • Honda H; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
Neuroradiology ; 61(9): 979-989, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31016367
PURPOSE: To evaluate the performance of acceleration-selective arterial spin labeling (AccASL) MR angiography in the visualization of brain arteriovenous malformations (AVMs) in comparison with digital subtraction angiography (DSA) and time-of-flight (TOF) MR angiography. METHODS: Twenty-one patients with brain AVM (mean age 31.1 ± 18.6 years; 11 males, 10 females) underwent TOF and AccASL MR angiography and DSA. Two neuroradiologists conducted an observer study for detection, nidus size, eloquence, venous drainage pattern, and Spetzler-Martin (SM) grade. The evaluations included the visualization of each AVM component with reference to DSA and assessments of contrast-to-noise ratio (CNR). The kappa statistic, repeated measures analysis of variance, Wilcoxon matched pairs test, and paired t test were used. RESULTS: Both observers detected more AVMs with AccASL (95.2%, 90.5% for Observers 1 and 2) than with TOF (76.2% and 71.4%, respectively). The inter-modality agreement between AccASL and DSA was almost perfect for the eloquence, venous drainage pattern, and SM grade for Observer 1 and moderate for the venous drainage pattern and substantial for the eloquence and SM grade for Observer 2. The visualization scores were higher with AccASL than with TOF for the feeding artery (AccASL, 4.5 ± 1.0 vs. TOF, 3.9 ± 1.5, p = 0.0214), nidus (4.6 ± 1.1 vs. 3.2 ± 1.5, p = 0.0006), and draining vein (4.6 ± 1.0 vs. 2.2 ± 1.1, p < 0.0001), respectively. The CNRs in the nidus were higher in AccASL than in TOF (29.9 ± 16.7 vs. 20.8 ± 16.5, p = 0.0002), as in the draining vein (23.2 ± 13.0 vs. 12.6 ± 12.0, p = 0.0010), respectively. CONCLUSIONS: AccASL better visualized brain AVMs compared with TOF and was useful for grading without the use of contrast agents.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Malformações Arteriovenosas Intracranianas / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Malformações Arteriovenosas Intracranianas / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão País de publicação: Alemanha