The aCORN Backscatter-Suppressed Beta Spectrometer.
Hassan, M T; Bateman, F; Collett, B; Darius, G; DeAngelis, C; Dewey, M S; Jones, G L; Komives, A; Laptev, A; Mendenhall, M P; Nico, J S; Noid, G; Stephenson, E J; Stern, I; Trull, C; Wietfeldt, F E.
Afiliação
  • Hassan MT; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • Bateman F; National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
  • Collett B; Physics Department, Hamilton College, Clinton, NY 13323, USA.
  • Darius G; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • DeAngelis C; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • Dewey MS; National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
  • Jones GL; Physics Department, Hamilton College, Clinton, NY 13323, USA.
  • Komives A; Department of Physics and Astronomy, DePauw University, Greencastle, IN 46135, USA.
  • Laptev A; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • Mendenhall MP; National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
  • Nico JS; National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
  • Noid G; CEEM, Indiana University, Bloomington, IN 47408, USA.
  • Stephenson EJ; CEEM, Indiana University, Bloomington, IN 47408, USA.
  • Stern I; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • Trull C; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
  • Wietfeldt FE; Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118, USA.
Article em En | MEDLINE | ID: mdl-31092963
ABSTRACT
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electronantineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.