Your browser doesn't support javascript.
loading
Multifunctional microchip-based distillation apparatus II - Aerated distillation for sulfur dioxide detection.
Dayao, Loise Ann N; Liu, Chan-Chiung; Hsu, Sheng-Yen; Tayo, Lemmuel L; Ju, Wei-Jhong; Fu, Lung-Ming.
Afiliação
  • Dayao LAN; School of Chemical Engineering and Chemistry, Mapúa University, Manila, 1002, Philippines.
  • Liu CC; Department of Food Science, National Pingtung University of Science and Technology, Pingtung, 912, Taiwan.
  • Hsu SY; Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-sen University, Kaohsiung, 804, Taiwan.
  • Tayo LL; School of Chemical Engineering and Chemistry, Mapúa University, Manila, 1002, Philippines.
  • Ju WJ; Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan.
  • Fu LM; Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan; Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung, 912, Taiwan. Electronic address: loudyfu@mail.ncku.edu.tw.
Anal Chim Acta ; 1071: 44-52, 2019 Sep 13.
Article em En | MEDLINE | ID: mdl-31128754
ABSTRACT
A multifunctional microchip-based distillation apparatus is presented for the distilled of sulfur dioxide (SO2) in food products. The microchip is fabricated on poly(methyl methacrylate) (PMMA) substrates, and comprises a sample zone, a buffer zone, a serpentine distillation column, and a collection zone. In the process, the sample is introduced into the sample zone and is heated under carefully controlled temperature and time conditions. The resulting SO2 and water vapor are carried by nitrogen (N2) gas to the distillation column, where the SO2 is separated from the water vapor via the condensing effects of a continuous cold water flow. Finally, the SO2 is transported to the collection zone, where it is collected with hydrogen peroxide (H2O2) and its concentration determined using an alkali-based titration and paper-based detection method. A distillation efficiency of 90.5% is obtained under the optimal distillation conditions at concentrations of 20-4000 ppm. Moreover, a linear correlation (R2 = 0.9997) is observed between the experimental measurements of the SO2 concentration and the known concentration. The validity of the presented microchip-based distillation apparatus is further investigated by distilling the SO2 concentrations of 25 commodity samples. The detection results show that the deviation does not exceed 5.4% compared with the traditional official method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Enxofre / Destilação / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Filipinas

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dióxido de Enxofre / Destilação / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Filipinas