Your browser doesn't support javascript.
loading
[Impacts of Different Nostril for Nasotracheal Intubation with Video Laryngoscopy].
Wang, Lei; Sui, Jing Hu; Deng, Xiao Ming; Xu, Wen Li; Chen, Ke Yu; Wei, Ling Xin; Yang, Dong.
Afiliação
  • Wang L; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Sui JH; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Deng XM; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Xu WL; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Chen KY; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Wei LX; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
  • Yang D; Department of Anesthesiology,Plastic Surgery Hospital,CAMS and PUMC,Beijing 100144,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 41(3): 379-382, 2019 Jun 30.
Article em Zh | MEDLINE | ID: mdl-31282333
Objective To compare the impacts of different nostril on nasotracheal intubation with video laryngoscopy.Methods Totally 120 ASA grade I maxillofacial surgery patients were equally randomized into two groups:group A(left nostril)and group B(right nostril).After rapid induction of anesthesia,the nasal intubation was completed by Tosight video laryngoscope,and the success rate of the first attempt of the tube passing through the nasal cavity was recorded and compared between these two groups.In addition,time of tube through nasal cavity,time of glottis exposure,total intubation time,intubation success rate,and nasal bleeding were recorded.Results The success rate of the first attempt of tube passing through the nasal cavity was not significantly different between groups A and B(84.7% vs. 81.7%;χ 2=0.202,P=0.653).The time of tube passing through nasal cavity [(7.3±4.6)s vs.(7.5±4.1)s;t=-0.223,P=0.824] and the time of glottic exposure [(6.6±1.4)s vs.(6.7±1.4)s;t=-0.348,P=0.728] had no significant differences between two groups.The success rates of first intubation attempt were 100% in both groups.The total intubation time was(35.1±9.2)s in group A and(34.0±7.8)s in group B(t=0.663,P=0.509).Intubation-related epistaxis was found in 16 cases(27.1%)in group A and in 17 cases(28.3%)in group B(χ 2 =0.022,P=0.882).Conclusion Different nasal approaches have no effect on nasal intubation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intubação Intratraqueal / Laringoscopia / Cavidade Nasal Tipo de estudo: Clinical_trials Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China País de publicação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intubação Intratraqueal / Laringoscopia / Cavidade Nasal Tipo de estudo: Clinical_trials Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China País de publicação: China