Type IIIB endoleak from stent suture lines of a thoracic endograft.
J Vasc Surg Cases Innov Tech
; 5(3): 214-217, 2019 Sep.
Article
em En
| MEDLINE
| ID: mdl-31289766
ABSTRACT
We report a case of a patient with type IIIB endoleak after thoracic endovascular aortic repair that remained undetected by computed tomography and was first diagnosed during open conversion surgery. The aneurysm enlarged gradually from 60 to 78 mm without type I and type II endoleaks during 3 to 6 years after thoracic endovascular aortic repair. Type IIIB endoleaks from nitinol stent suture lines were detected, and the endograft was then explanted and replaced by a vascular graft.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Revista:
J Vasc Surg Cases Innov Tech
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
Japão