Simultaneous ultra-performance liquid chromatography-tandem mass spectrometry determination of six components in rat plasma after oral administration of Smilacis glabrae Roxb. extract.
Xie, Jing; Li, Li; Shi, Yurui; Chen, Rongda; Liu, Guiming; Wang, Mengxue; Zheng, Meizhu; Zhang, Ning.
Afiliação
  • Xie J; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Li L; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Shi Y; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Chen R; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Liu G; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Wang M; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Zheng M; Laboratory of Chemistry Analytical, Department of Chemical Analysis,, College of Changchun Normal University, Changchun, China.
  • Zhang N; Key Laboratory of Chinese Materia Medica (Ministry of Education),Department of Pharmaceutical Analysis, College of Jiamusi, Heilongjiang University of Chinese Medicine, Harbin, China.
Biomed Chromatogr ; 33(12): e4680, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31415097
ABSTRACT
In this study, an accurate and reliable method of ultra-performance liquid chromatography coupled with a triple-quadrupole tandem mass spectrometry was firstly developed and fully validated for the simultaneous determination of epicatechin, neoastilbin, astilbin, isoastilbin, engeletin and resveratrol in rat plasma after administration of Smilacis glabrae Roxb. extract. Naringenin was used as an internal standard (IS). The analyte and IS were separated on a C18 column by gradient elution with a mobile phase of acetonitrile-0.3% acetic acid at a flow rate of 0.25 mL/min for a total run time of 8 min. The method was validated in terms of selectivity, linearity, precision, accuracy, extraction recovery, matrix effect and stability. The developed method was successfully applied to determine the main pharmacokinetic parameters of six components in rat plasma.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medicamentos de Ervas Chinesas / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medicamentos de Ervas Chinesas / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China