In vitro RHE skin sensitisation assays: Applicability to challenging substances.
Mehling, A; Adriaens, E; Casati, S; Hubesch, B; Irizar, A; Klaric, M; Letasiova, S; Manou, I; Müller, B P; Roggen, E; van Vliet, E; Basketter, D.
Afiliação
  • Mehling A; BASF Personal Care and Nutrition GmbH, Duesseldorf, Germany.
  • Adriaens E; Adriaens Consulting BVBA, Aalter, Belgium.
  • Casati S; European Commission, Joint Research Centre (JRC), Ispra, Italy.
  • Hubesch B; Hubesch Consult BVBA, Sint-Pieters-Leeuw, Belgium, European Chemical Industry Council (Cefic), Brussels, Belgium.
  • Irizar A; The International Fragrance Association (IFRA), Geneva, Switzerland.
  • Klaric M; Cosmetics Europe, Brussels, Belgium.
  • Letasiova S; MatTek In Vitro Life Science Laboratories, Bratislava, Slovakia.
  • Manou I; European Partnership for Alternative Approaches to Animal Testing (EPAA), Brussels, Belgium.
  • Müller BP; Symrise AG, Holzminden, Germany.
  • Roggen E; 3Rs Management and Consulting ApS, Kongens Lydngby, Denmark.
  • van Vliet E; Cosmetics Europe, Brussels, Belgium.
  • Basketter D; DABMEB Consultancy Ltd, Sharnbrook, UK. Electronic address: dabmebconsultancyltd@me.com.
Regul Toxicol Pharmacol ; 108: 104473, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31494190
ABSTRACT
In the last 20 years, alternative approaches to the identification of skin sensitisation hazards have been at the forefront of the 3Rs and have helped refine the validation and acceptance processes. However, experience with the local lymph node assay showed that, post-validation, challenges still occurred, particularly when a wider diversity of chemical substances was addressed, a situation which will arise with validated in vitro alternatives. In the present work, a range of substances potentially challenging to assess in current nonanimal OECD test guidelines were evaluated in several of the emerging in vitro alternatives. Twelve such substances (of which just over half were known skin sensitisers) were assessed in 4 assays, all based on reconstructed human epidermis (RHE) models. For hazard identification, the overall predictive accuracy ranged around 70% for three assays, although for one (SensCeeTox), it fell below 50% when human data was used as the benchmark. In most cases, sensitivity was high, such that sensitisation was overpredicted. As the substances were challenging to assess in other nonanimal methods, the results indicate that the 3D RHE models may be a useful tool for assessing skin sensitisation potentials without needing to revert to animal use.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bioensaio / Epiderme / Haptenos / Alternativas aos Testes com Animais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Regul Toxicol Pharmacol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bioensaio / Epiderme / Haptenos / Alternativas aos Testes com Animais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Regul Toxicol Pharmacol Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha