Your browser doesn't support javascript.
loading
A Zero-Cross Detection Algorithm for Cavity-Length Interrogation of Fiber-Optic Fabry-Perot Sensors.
Ma, Zhibo; Song, Zechen; Huang, Xirui; Guo, Tongxin; Yuan, Weizheng; Chen, Haibin; Zhang, Tianyang; Wang, Wei.
Afiliação
  • Ma Z; Key Lab of Micro/Nano Systems for Aerospace, Ministry of Education, Northwestern Polytechnical University, Xi'an 710072, China. zbma@nwpu.edu.cn.
  • Song Z; Shaanxi Key Lab of MEMS/NEMS, Northwestern Polytechnical University, Xi'an 710072, China. zbma@nwpu.edu.cn.
  • Huang X; Key Lab of Micro/Nano Systems for Aerospace, Ministry of Education, Northwestern Polytechnical University, Xi'an 710072, China. zechen_song@foxmail.com.
  • Guo T; Shaanxi Key Lab of MEMS/NEMS, Northwestern Polytechnical University, Xi'an 710072, China. zechen_song@foxmail.com.
  • Yuan W; School of Optoelectronic Engineering, Xi'an Technological University, Xi'an 710021, China. huangxrxatu@163.com.
  • Chen H; Shaanxi Province Key Lab of Photoelectric Measurement and Instrument Technology, Xi'an Technological University, Xi'an 710021, China. huangxrxatu@163.com.
  • Zhang T; Key Lab of Micro/Nano Systems for Aerospace, Ministry of Education, Northwestern Polytechnical University, Xi'an 710072, China. guo-tx9199@mail.nwpu.edu.cn.
  • Wang W; Shaanxi Key Lab of MEMS/NEMS, Northwestern Polytechnical University, Xi'an 710072, China. guo-tx9199@mail.nwpu.edu.cn.
Sensors (Basel) ; 19(18)2019 Sep 07.
Article em En | MEDLINE | ID: mdl-31500318
ABSTRACT
A zero-cross detection algorithm was proposed for the cavity-length interrogation of fiber-optic Fabry-Perot (FP) sensors. The method can avoid the inaccuracy of peak determination in the conventional peak-to-peak method for the cavity-length interrogation of fiber-optic FP sensors caused by the slow variation of the spectral power density in peak neighboring regions. Both simulations and experiments were carried out to investigate the feasibility and performance of the zero-cross detection algorithm. Fiber-optic FP sensors with cavity lengths in the range of 150-1000 µm were successfully interrogated with a maximum error of 0.083 µm.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China