Improved off-resonance phase behavior using a phase-inverted adiabatic half-passage pulse for 13 C MRS in humans at 7 T.
Serés Roig, Eulalia; Xin, Lijing; Gallichan, Daniel; Mlynarik, Vladimir; Gruetter, Rolf.
Afiliação
  • Serés Roig E; Laboratory of Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne (EPFL), Switzerland.
  • Xin L; Centre d'Imagerie Biomédicale-Animal and Imaging Technology (CIBM-AIT), Lausanne, Switzerland.
  • Gallichan D; Centre d'Imagerie Biomédicale-Animal and Imaging Technology (CIBM-AIT), Lausanne, Switzerland.
  • Mlynarik V; High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Gruetter R; Laboratory of Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne (EPFL), Switzerland.
NMR Biomed ; 32(12): e4171, 2019 12.
Article em En | MEDLINE | ID: mdl-31517419
In vivo 13 C MRS at high field benefits from an improved SNR and spectral resolution especially when using surface coils in combination with adiabatic pulses, such as the adiabatic half-passage (AHP) pulse for 13 C excitation. However, the excitation profile of the AHP pulse is asymmetric relative to the carrier frequency, which could lead to asymmetric excitation of the spectral lines relative to the center of the spectrum. In this study, a pulse-acquire sequence was designed for adiabatic 13 C excitation with a symmetric bandwidth, utilizing a combination of two AHP pulses with inverted phases in alternate scans. Magnetization and phase behavior as a function of frequency offset and RF amplitude of the B1 field, as well as the steady-state transverse magnetization response to off-resonance, were simulated. Excitation properties of the combined pulse sequence were studied by 23 Na imaging and 13 C spectroscopy in vitro on a phantom and in vivo on the human calf at 7 T. Simulations demonstrated symmetric transverse magnetization and phase with respect to positive and negative frequency offsets when using two AHP pulses with inverted phases in alternate scans, thereby minimizing baseline distortion and achieving symmetric T1 weighting, as confirmed by in vitro measurements. The intensities of the lipid peaks at 15, 30, 62, 73, and 130 ppm were in agreement with those theoretically predicted using two AHP pulses with inverted phases in alternate scans. We conclude that using two phase-inverted AHP pulses improves the symmetry of the 13 C excitation profile and phase response to off-resonance effects at 7 T in comparison with using a single AHP pulse.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 Tipo de estudo: Prognostic_studies Limite: Humans / Male Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 Tipo de estudo: Prognostic_studies Limite: Humans / Male Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça País de publicação: Reino Unido