Your browser doesn't support javascript.
loading
Value of magnetic resonance/computed tomography peritoneography technique in the evaluation of dialysate leakage and hernia following peritoneal dialysis.
Theodorou, Daphne J; Theodorou, Stavroula J; Mantzoukis, Fotios; Androulaki, Marianthi; Kokkolou, Elissavet; Andrikos, Emilios; Sferopoulos, Georgios.
Afiliação
  • Theodorou DJ; Department of Radiology, MRI-CT Section, General Hospital of Ioannina and National Healthcare System, Ioannina, Greece.
  • Theodorou SJ; Department of Radiology, University Hospital of Ioannina, Ioannina, Greece.
  • Mantzoukis F; Department of Radiology, MRI-CT Section, General Hospital of Ioannina and National Healthcare System, Ioannina, Greece.
  • Androulaki M; Department of Nephrology, Hemodialysis Unit, General Hospital of Ioannina, Ioannina, Greece.
  • Kokkolou E; Department of Nephrology, Hemodialysis Unit, General Hospital of Ioannina, Ioannina, Greece.
  • Andrikos E; Department of Nephrology, Hemodialysis Unit, General Hospital of Ioannina, Ioannina, Greece.
  • Sferopoulos G; Department of Nephrology, Hemodialysis Unit, General Hospital of Ioannina, Ioannina, Greece.
Int J Artif Organs ; 43(2): 94-98, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31544578
ABSTRACT
Magnetic resonance and computed tomography peritoneography are diagnostic imaging procedures that involve the intraperitoneal administration of a mixture of contrast material and dialysate for direct visualization of the peritoneal cavity and assessment of the integrity of peritoneal membrane. In a clinical series of patients with end-stage renal disease treated with continuous ambulatory peritoneal dialysis, who presented with genital or low abdominal edema, advanced peritoneographic imaging studies allowed direct visualization of the dialysate leakage and peritoneal hernias. Both magnetic resonance and computed tomography peritoneographic procedures allowed accurate diagnosis of continuous ambulatory peritoneal dialysis-related complications that may need to be addressed promptly so that the effectiveness of continuous ambulatory peritoneal dialysis is not compromised.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cavidade Peritoneal / Imageamento por Ressonância Magnética / Soluções para Diálise / Tomografia Computadorizada por Raios X / Diálise Peritoneal Ambulatorial Contínua / Edema / Hérnia Tipo de estudo: Etiology_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Int J Artif Organs Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Grécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cavidade Peritoneal / Imageamento por Ressonância Magnética / Soluções para Diálise / Tomografia Computadorizada por Raios X / Diálise Peritoneal Ambulatorial Contínua / Edema / Hérnia Tipo de estudo: Etiology_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Int J Artif Organs Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Grécia