Your browser doesn't support javascript.
loading
Passive monitoring of nonlinear relaxation of cracked polymer concrete samples using acoustic emission.
Yu, Xiaoyang; Bentahar, Mourad; Mechri, Charfeddine; Montrésor, Silvio.
Afiliação
  • Yu X; Laboratoire d'Acoustique de l'Université du Mans, UMR-CNRS 6613, Le Mans Université, Av. Olivier Messiaen, 72085 Le Mans Cedex 9, Francexiaoyang.yu@univ-lemans.fr, mourad.bentahar@univ-lemans.fr, cherfeddine.mechri@univ-lemans.fr, silvio.montresor@univ-lemans.fr.
  • Bentahar M; Laboratoire d'Acoustique de l'Université du Mans, UMR-CNRS 6613, Le Mans Université, Av. Olivier Messiaen, 72085 Le Mans Cedex 9, Francexiaoyang.yu@univ-lemans.fr, mourad.bentahar@univ-lemans.fr, cherfeddine.mechri@univ-lemans.fr, silvio.montresor@univ-lemans.fr.
  • Mechri C; Laboratoire d'Acoustique de l'Université du Mans, UMR-CNRS 6613, Le Mans Université, Av. Olivier Messiaen, 72085 Le Mans Cedex 9, Francexiaoyang.yu@univ-lemans.fr, mourad.bentahar@univ-lemans.fr, cherfeddine.mechri@univ-lemans.fr, silvio.montresor@univ-lemans.fr.
  • Montrésor S; Laboratoire d'Acoustique de l'Université du Mans, UMR-CNRS 6613, Le Mans Université, Av. Olivier Messiaen, 72085 Le Mans Cedex 9, Francexiaoyang.yu@univ-lemans.fr, mourad.bentahar@univ-lemans.fr, cherfeddine.mechri@univ-lemans.fr, silvio.montresor@univ-lemans.fr.
J Acoust Soc Am ; 146(4): EL323, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31671964
ABSTRACT
This work presents an acoustic emission (AE) monitoring of slow dynamics in micro-cracked polymer concrete (PC) samples. In order to obtain calibrated damage states, AE was first used to characterize the micro-damage mechanisms in real time when PC samples are submitted to three-point bending tests. Then, an unsupervised classification of AE data based on the Principle Component Analysis and the k-means clustering was applied to classify AE data. The AE monitoring of the nonlinear relaxation of PC samples revealed the existence of a silence period followed by AE hits belonging to two different damage classes. A similarity appeared between the properties of the detected AE hits obtained during the nonlinear relaxation and the quasi-static tests. Finally, this work shows that the dynamics of both mechanisms during the nonlinear relaxation are clearly different.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2019 Tipo de documento: Article