Your browser doesn't support javascript.
loading
Efficacy and safety of MYL-1501D versus insulin glargine in people with type 1 diabetes mellitus: Results of the INSTRIDE 3 phase 3 switch study.
Blevins, Thomas C; Barve, Abhijit; Raiter, Yaron; Aubonnet, Patrick; Athalye, Sandeep; Sun, Bin; Muniz, Rafael.
Afiliação
  • Blevins TC; Texas Diabetes and Endocrinology, Austin, Texas, United States.
  • Barve A; Mylan Inc, Canonsburg, Pennsylvania, United States.
  • Raiter Y; Mylan EPD, Amstelveen, The Netherlands.
  • Aubonnet P; Mylan EPD, Steinhausen, Switzerland.
  • Athalye S; Biocon Research Limited, Bangalore, India.
  • Sun B; Mylan Inc, Canonsburg, Pennsylvania, United States.
  • Muniz R; Mylan Inc, Canonsburg, Pennsylvania, United States.
Diabetes Obes Metab ; 22(3): 365-372, 2020 03.
Article em En | MEDLINE | ID: mdl-31691472
ABSTRACT

AIMS:

To assess the efficacy, insulin dose, safety and immunogenicity when people with type 1 diabetes mellitus switched between MYL-1501D and reference insulin glargine (Lantus®; Sanofi-Aventis US LLC, Bridgewater, New Jersey). MATERIALS AND

METHODS:

Eligible participants from INSTRIDE 1 who completed 52 weeks of reference insulin glargine treatment were randomized 11 to the reference sequence (n = 63; reference insulin glargine for 36 weeks) or to the treatment-switching sequence (n = 64; MYL-1501D [weeks 0-12], reference insulin glargine [weeks 12-24] and MYL-1501D [weeks 24-36]). Change in glycated haemoglobin (HbA1c) from baseline to week 36 was the primary efficacy endpoint used to demonstrate equivalence between the two treatment sequences. Secondary endpoints included change in fasting plasma glucose (FPG), self-monitored blood glucose (SMBG) and insulin dose; immunogenicity; and adverse events, including hypoglycaemia.

RESULTS:

Mean changes in HbA1c (least squares [LS] mean [SE]) from baseline to week 36 were -0.05 (0.032) and -0.06 (0.034) for the treatment-switching and reference sequences, respectively (LS mean difference 0.01 [95% CI -0.085 to 0.101]). Treatment sequences were comparable in terms of secondary endpoints, including FPG, SMBG and insulin dose, and the safety and immunogenicity profiles of the two sequences were similar.

CONCLUSIONS:

Switching participants between MYL-1501D and reference insulin glargine demonstrated equivalent efficacy and similar safety and immunogenicity, showing that people taking reference insulin glargine can safely switch to MYL-1501D.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 1 Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Diabetes Obes Metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 1 Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Diabetes Obes Metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos