Your browser doesn't support javascript.
loading
Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery: Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE).
Reddy, Vivek Y; Schilling, Richard; Grimaldi, Massimo; Horton, Rodney; Natale, Andrea; Riva, Stefania; Tondo, Claudio; Kuck, Karl-Heinz; Neuzil, Petr; McInnis, Kendra; Bishara, Moe; Zhang, Baohui; Govari, Assaf; Abdelaal, Ahmed; Mansour, Moussa.
Afiliação
  • Reddy VY; Icahn School of Medicine at Mount Sinai, New York, NY (V.Y.R.).
  • Schilling R; Homolka Hospital, Prague, Czech Republic (V.Y.R., P.N.).
  • Grimaldi M; Health NHS Trust St, Bartholomew's Hospital West, London, United Kingdom (R.S.).
  • Horton R; Generale Regionale F. Miulli, Bari, Italy (M.G.).
  • Natale A; Texas Cardiac Arrhythmia Institute, Austin (R.H., A.N.).
  • Riva S; Texas Cardiac Arrhythmia Institute, Austin (R.H., A.N.).
  • Tondo C; Centro Cardiologico Monzino, Milan, Italy (S.R., C.T.).
  • Kuck KH; Centro Cardiologico Monzino, Milan, Italy (S.R., C.T.).
  • Neuzil P; Asklepios Hospital St Georg Cardiology, Hamburg, Germany (K.-H.K.).
  • McInnis K; Homolka Hospital, Prague, Czech Republic (V.Y.R., P.N.).
  • Bishara M; Biosense Webster Inc, Irvine, CA (K.M., M.B., B.Z., A.G., A.A.).
  • Zhang B; Biosense Webster Inc, Irvine, CA (K.M., M.B., B.Z., A.G., A.A.).
  • Govari A; Biosense Webster Inc, Irvine, CA (K.M., M.B., B.Z., A.G., A.A.).
  • Abdelaal A; Biosense Webster Inc, Irvine, CA (K.M., M.B., B.Z., A.G., A.A.).
  • Mansour M; Biosense Webster Inc, Irvine, CA (K.M., M.B., B.Z., A.G., A.A.).
Circ Arrhythm Electrophysiol ; 12(12): e007541, 2019 12.
Article em En | MEDLINE | ID: mdl-31826648
BACKGROUND: Balloon catheters facilitate pulmonary vein (PV) isolation, but current technology is limited by either a single ablative element, potentially leading to over-ablation of thin and under-ablation of thick tissue, or prolonged procedure times. Visualized by electroanatomical mapping, a novel compliant radiofrequency balloon catheter with 10 irrigated, flexible electrodes can simultaneously and independently deliver energy. Herein, we evaluated the feasibility, safety, and short-term efficacy of this radiofrequency balloon in a multicenter, single-arm, first-in-human study. METHODS: Paroxysmal atrial fibrillation patients underwent PV isolation with the radiofrequency balloon delivered over-the-wire with a deflectable 13.5F sheath. Radiofrequency energy is delivered simultaneously from all electrodes-up to 30 s posteriorly and 60 s anteriorly. Esophageal temperature was monitored in all patients; the esophagus was also mechanically deviated in 10 patients. RESULTS: At 4 sites, 39 patients were treated by 9 operators. The radiofrequency balloon isolated all targeted PVs (152/152), 79.6% with a single application. Electrical reconnection occurred in only 7/150 PVs (4.7%) on adenosine/isoproterenol challenge. Mean procedure, balloon dwell, and fluoroscopy times were 101.6, 40.5, and 17.4 min, respectively. Esophagogastroduodenoscopy revealed asymptomatic esophageal erythema in 5 patients. Phrenic nerve palsy occurred in a patient in whom phrenic pacing was inadvertently omitted. At 3 months, imaging revealed no PV stenosis, and early atrial arrhythmia recurrence occurred in only 10/39 (25.6%) patients. CONCLUSIONS: The compliant radiofrequency balloon can directionally tailor energy delivery for efficient, effective, and reasonably safe acute PV isolation. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: ISRCTN 11764506.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Cateterismo Cardíaco / Ablação por Cateter / Cateteres Cardíacos / Frequência Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte / Europa Idioma: En Revista: Circ Arrhythm Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Cateterismo Cardíaco / Ablação por Cateter / Cateteres Cardíacos / Frequência Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte / Europa Idioma: En Revista: Circ Arrhythm Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de publicação: Estados Unidos