Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery: Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE).
Circ Arrhythm Electrophysiol
; 12(12): e007541, 2019 12.
Article
em En
| MEDLINE
| ID: mdl-31826648
BACKGROUND: Balloon catheters facilitate pulmonary vein (PV) isolation, but current technology is limited by either a single ablative element, potentially leading to over-ablation of thin and under-ablation of thick tissue, or prolonged procedure times. Visualized by electroanatomical mapping, a novel compliant radiofrequency balloon catheter with 10 irrigated, flexible electrodes can simultaneously and independently deliver energy. Herein, we evaluated the feasibility, safety, and short-term efficacy of this radiofrequency balloon in a multicenter, single-arm, first-in-human study. METHODS: Paroxysmal atrial fibrillation patients underwent PV isolation with the radiofrequency balloon delivered over-the-wire with a deflectable 13.5F sheath. Radiofrequency energy is delivered simultaneously from all electrodes-up to 30 s posteriorly and 60 s anteriorly. Esophageal temperature was monitored in all patients; the esophagus was also mechanically deviated in 10 patients. RESULTS: At 4 sites, 39 patients were treated by 9 operators. The radiofrequency balloon isolated all targeted PVs (152/152), 79.6% with a single application. Electrical reconnection occurred in only 7/150 PVs (4.7%) on adenosine/isoproterenol challenge. Mean procedure, balloon dwell, and fluoroscopy times were 101.6, 40.5, and 17.4 min, respectively. Esophagogastroduodenoscopy revealed asymptomatic esophageal erythema in 5 patients. Phrenic nerve palsy occurred in a patient in whom phrenic pacing was inadvertently omitted. At 3 months, imaging revealed no PV stenosis, and early atrial arrhythmia recurrence occurred in only 10/39 (25.6%) patients. CONCLUSIONS: The compliant radiofrequency balloon can directionally tailor energy delivery for efficient, effective, and reasonably safe acute PV isolation. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: ISRCTN 11764506.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Veias Pulmonares
/
Fibrilação Atrial
/
Cateterismo Cardíaco
/
Ablação por Cateter
/
Cateteres Cardíacos
/
Frequência Cardíaca
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
/
Prognostic_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
America do norte
/
Europa
Idioma:
En
Revista:
Circ Arrhythm Electrophysiol
Assunto da revista:
ANGIOLOGIA
/
CARDIOLOGIA
Ano de publicação:
2019
Tipo de documento:
Article
País de publicação:
Estados Unidos