Your browser doesn't support javascript.
loading
Validity and inter-observers reliability of blood pressure measurements using mercury sphygmomanometer in the PERSIAN Guilan cohort study.
Joukar, Farahnaz; Naghipour, Mohammad Reza; Yeganeh, Sara; Sepehrimanesh, Masood; Keshtkar, Abbasali; Ashoobi, Mohammad Taghi; Hassanipour, Soheil; Mansour-Ghanaei, Fariborz.
Afiliação
  • Joukar F; Gastrointestinal and Liver Diseases Research Center, Guilan University of Medical Sciences.
  • Naghipour MR; Gastrointestinal and Liver Diseases Research Center, Guilan University of Medical Sciences.
  • Yeganeh S; Caspian Digestive Disease Research Center, Guilan University of Medical Sciences, Rasht, Iran.
  • Sepehrimanesh M; Caspian Digestive Disease Research Center, Guilan University of Medical Sciences, Rasht, Iran.
  • Keshtkar A; Gastrointestinal and Liver Diseases Research Center, Guilan University of Medical Sciences.
  • Ashoobi MT; NIH Clinical Center, Certified Protein and Proteomics specialist, Postdoctoral Fellowship at University of Louisiana at Lafayette, Louisiana, USA.
  • Hassanipour S; Department of Health Science Education Development, School of Public Health, Tehran University of Medical Sciences, Tehran.
  • Mansour-Ghanaei F; Gastrointestinal and Liver Diseases Research Center, Guilan University of Medical Sciences.
Blood Press Monit ; 25(2): 100-104, 2020 Apr.
Article em En | MEDLINE | ID: mdl-31842184
ABSTRACT

OBJECTIVE:

Accurate measuring of blood pressure is a vital step in both clinical and para-clinical settings. The aims of the present study were to evaluate the validity and inter-observer reliability of measured blood pressures by two trained observers and one expert supervisor in the PERSIAN Guilan cohort study (PGCS). PARTICIPANTS AND

METHODS:

In a quasi-experimental study, two trained observers and one expert supervisor measured systolic and diastolic blood pressures (SBP and DBP) in 85 included participants. All measurements were done using Riester mercury sphygmomanometer as duplicate for each people.

RESULTS:

Lack of validity in the total SBP (P = 0.017), DBP in age <50 years (P = 0.039), and DBP in BMI >25 (P=0.019) of first observer and total SBP (P = 0.045), SBP of male (P = 0.019), both SBP and DBP in age >50 years (P = 0.034, P = 0.012) and DBP in BMI <25 (P = 0.001) of second observer were seen. In addition, total inter-rater reliability was found as 12.2% and 27.2% in SBP and DBP, respectively. Age, sex and BMI categorized inter-observer reliability were not more than 15% in SBP of BMI <25 kg/m and 31.6% in DBP of female. The final inter-observer agreement after educational course was higher than 0.7 totally and in all categorical evaluations.

CONCLUSION:

Based on lack of validity in some conditions and low level of reliability, education of all observers to measure both SBP and DBP accurately is needed. This is more necessary to done before performing the high population surveys.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pressão Sanguínea Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Revista: Blood Press Monit Assunto da revista: ANGIOLOGIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pressão Sanguínea Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Revista: Blood Press Monit Assunto da revista: ANGIOLOGIA Ano de publicação: 2020 Tipo de documento: Article