Your browser doesn't support javascript.
loading
Vascular Landmark-Based Method for Highly Reproducible Measurement of Left Atrial Appendage Volume in Computed Tomography.
Schluchter, Andrew; Jan, Chelsea; Lowe, Katherine; Vigneault, Davis M; Contijoch, Francisco; McVeigh, Elliot R.
Afiliação
  • Schluchter A; Departments of Bioengineering (A.S., C.J., K.L., D.M.V., F.C., E.R.M.), UC San Diego, La Jolla, CA.
  • Jan C; Departments of Bioengineering (A.S., C.J., K.L., D.M.V., F.C., E.R.M.), UC San Diego, La Jolla, CA.
  • Lowe K; Departments of Bioengineering (A.S., C.J., K.L., D.M.V., F.C., E.R.M.), UC San Diego, La Jolla, CA.
  • Vigneault DM; Departments of Bioengineering (A.S., C.J., K.L., D.M.V., F.C., E.R.M.), UC San Diego, La Jolla, CA.
  • Contijoch F; Sackler School of Graduate Biomedical Sciences, Tufts University School of Medicine, Boston, MA (D.M.V.).
  • McVeigh ER; Departments of Bioengineering (A.S., C.J., K.L., D.M.V., F.C., E.R.M.), UC San Diego, La Jolla, CA.
Circ Cardiovasc Imaging ; 12(12): e009075, 2019 12.
Article em En | MEDLINE | ID: mdl-31842587
ABSTRACT

BACKGROUND:

Modern computed tomographic scanning can produce 4-dimensional images of the left atrial appendage (LAA). LAA function and morphology can then be measured, to plan interventions such as occlusion and to evaluate LAA flow for thrombogenic risk analysis. A current problem here is defining a reproducible boundary between the LAA and the left atrium.

METHODS:

This study used retrospectively gated 4-dimensional computed tomographic data from 25 implantation and coronary artery imaging patients. In each patient, the LAA ostium was defined at multiple time points during the RR interval. To examine the reproducibility of the definition of the LAA ostium, 3 observers analyzed all time frames in each patient 3 times. Five nonconsecutive time frames from each patient were then compared using intraclass correlation coefficients to quantify the precision of the method across patients. The correlation of LAA volumes for each time frame of each patient was determined across the different observers (interobserver) and within each observer's own data sets (intraobserver).

RESULTS:

The method was successful in 92% of patients. Two-way random-effect, absolute-agreement, single-measurement intraclass correlation coefficients for interobserver measurements were 0.984, 0.990, and 0.988, with intraobserver intraclass correlation coefficients of 0.989, 0.989, and 0.995. The intraclass correlation coefficient of all observations was 0.988.

CONCLUSIONS:

Classification of the LAA ostium using a stepwise procedure identifying the coumadin ridge and 2 vascular landmarks in ECG-gated computed tomography provides a viable method of establishing a highly reproducible boundary between the atrium and LAA needed to obtain LAA metrics useful for procedure planning and measuring LAA function.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Tomografia Computadorizada por Raios X / Função do Átrio Esquerdo / Apêndice Atrial / Imageamento Tridimensional Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Circ Cardiovasc Imaging Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Tomografia Computadorizada por Raios X / Função do Átrio Esquerdo / Apêndice Atrial / Imageamento Tridimensional Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Circ Cardiovasc Imaging Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Canadá