Your browser doesn't support javascript.
loading
[Control of Sludge Bulking Caused by Unknown Reason Through FeCl3 Coupled with Biochemical Methods].
Wei, Dong-Yang; Xiao, Cai-Lin; Zhou, Wen; Li, Rui-Hua; Cao, Qian.
Afiliação
  • Wei DY; Institute of Water Environmental Research, Chinese Research Academy of Environmental Sciences, Beijing 100012, China.
  • Xiao CL; South China Institute of Environmental Science, Ministry of Ecology and Environment, Guangzhou 510530, China.
  • Zhou W; Shenzhen Municipal Design & Research Institute Co., Ltd., Shenzhen 518029, China.
  • Li RH; South China Institute of Environmental Science, Ministry of Ecology and Environment, Guangzhou 510530, China.
  • Cao Q; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093, China.
Huan Jing Ke Xue ; 40(11): 5040-5047, 2019 Nov 08.
Article em Zh | MEDLINE | ID: mdl-31854572
ABSTRACT
Filamentous bulking could commonly influence effluent water quality in sewage treatment plants. Existing technologies are slowly effective, time consuming, and poorly adaptable. For now, enhancing organics substrates (COD) and dissolved oxygen (DO) concentration, adding FeCl3 into the reactor, and maintaining alternant aeration conditions are common methods to control filamentous bulking, but the effects of coupling techniques on the control of bulking are rarely reported. In this study, the filamentous bulking resulting from unintentionally erupted Candidatus Saccharibacteria was controlled by FeCl3 coupled with biochemical methods, which transforming step-feed A/O processes to the SBR process in the emergency by increasing DO to (7.45±0.49) mg·L-1 during aeration, enhancing COD to (332.73±106.06) mg·L-1, and adding FeCl3 into the reactor to set the starting concentration to 120 mg·L-1. As the results showed, FeCl3 coupled with the biochemical method quickly counteracted the bulking sludge mainly composed of Candidatus Saccharibacteria caused by unknown reason, while the Sludge Volume Index dropped from 274 mL·g-1 to 56 mL·g-1 within 14 days. The relative abundance of Candidatus Saccharibacteria decreased from 97.64% to 32.67% at the genus level because FeCl3 coupled with the biochemical method inhibited growth of Candidatus Saccharibacteria. Meanwhile, effluents of both COD and PO43--P met the effluent requirements of the I-A discharge standard in China and removal efficiency of NH4+-N increased from 65.33% to 74.65%. The results showed that FeCl3 coupled with the biochemical method exhibited good performance in the control of bulking caused by unknown reasons.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: Zh Revista: Huan Jing Ke Xue Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: Zh Revista: Huan Jing Ke Xue Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China