Your browser doesn't support javascript.
loading
MANTIS: A real-time quantitative multispectral imaging system for fusion plasmas.
Perek, A; Vijvers, W A J; Andrebe, Y; Classen, I G J; Duval, B P; Galperti, C; Harrison, J R; Linehan, B L; Ravensbergen, T; Verhaegh, K; de Baar, M R.
Afiliação
  • Perek A; Dutch Institute for Fundamental Energy Research (DIFFER), De Zaale 20, 5612 AJ Eindhoven, The Netherlands.
  • Vijvers WAJ; Dutch Institute for Fundamental Energy Research (DIFFER), De Zaale 20, 5612 AJ Eindhoven, The Netherlands.
  • Andrebe Y; Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Classen IGJ; Dutch Institute for Fundamental Energy Research (DIFFER), De Zaale 20, 5612 AJ Eindhoven, The Netherlands.
  • Duval BP; Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Galperti C; Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Harrison JR; CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB, United Kingdom.
  • Linehan BL; Plasma Science and Fusion Center, Massachusetts Institute of Technology, 77 Massachusetts Avenue, NW17, Cambridge, Massachusetts 02139, USA.
  • Ravensbergen T; Dutch Institute for Fundamental Energy Research (DIFFER), De Zaale 20, 5612 AJ Eindhoven, The Netherlands.
  • Verhaegh K; CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB, United Kingdom.
  • de Baar MR; Dutch Institute for Fundamental Energy Research (DIFFER), De Zaale 20, 5612 AJ Eindhoven, The Netherlands.
Rev Sci Instrum ; 90(12): 123514, 2019 Dec 01.
Article em En | MEDLINE | ID: mdl-31893833
ABSTRACT
This work presents a novel, real-time capable, 10-channel Multispectral Advanced Narrowband Tokamak Imaging System installed on the TCV tokamak, MANTIS. Software and hardware requirements are presented together with the complete system architecture. The image quality of the system is assessed with emphasis on effects resulting from the narrowband interference filters. Some filters are found to create internal reflection images that are correlated with the filters' reflection coefficient. This was measured for selected filters where significant absorption (up to 65% within ∼70 nm of the filter center) was measured. The majority of this was attributed to the filter's design, and several filters' performance is compared. Tailored real-time algorithms exploiting the system's capabilities are presented together with benchmarks comparing polling and event based synchronization. The real-time performance is demonstrated with a density ramp discharge performed on TCV. The behavior of spectral lines' emission from different plasma species and their interpretation are qualitatively described.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Holanda