Your browser doesn't support javascript.
loading
Subject-specific simulation for non-invasive assessment of aortic coarctation: Towards a translational approach.
Mercuri, Massimiliano; Wustmann, Kerstin; von Tengg-Kobligk, Hendrik; Göksu, Cemil; Hose, D Rodney; Narracott, Andrew.
Afiliação
  • Mercuri M; Mathematical Modelling in Medicine Group, Department of Infection, Immunity and Cardiovascular Science, University of Sheffield, Sheffield, United Kingdom; Therenva, Rennes, France; INSIGNEO Institute for in Silico Medicine, The University of Sheffield, Sheffield, U.K.. Electronic address: m.mercuri
  • Wustmann K; Center for Congenital Heart Disease, Cardiac Magnetic Resonance Imaging, Department of Cardiology, University Hospital Bern, Bern, Switzerland.
  • von Tengg-Kobligk H; Department of Diagnostic, Interventional and Pediatric Radiology, University of Bern, Bern University Hospital, Bern, Switzerland.
  • Göksu C; Therenva, Rennes, France.
  • Hose DR; Mathematical Modelling in Medicine Group, Department of Infection, Immunity and Cardiovascular Science, University of Sheffield, Sheffield, United Kingdom; Department of Diagnostic, Interventional and Pediatric Radiology, University of Bern, Bern University Hospital, Bern, Switzerland; Department of
  • Narracott A; Mathematical Modelling in Medicine Group, Department of Infection, Immunity and Cardiovascular Science, University of Sheffield, Sheffield, United Kingdom; INSIGNEO Institute for in Silico Medicine, The University of Sheffield, Sheffield, U.K.
Med Eng Phys ; 77: 69-79, 2020 03.
Article em En | MEDLINE | ID: mdl-31926831
ABSTRACT
We present a multi-scale CFD-based study conducted in a cohort of 11 patients with coarctation of the aorta (CoA). The study explores the potential for implementation of a workflow using non-invasive routinely collected medical imaging data and clinical measurements to provide a more detailed insight into local aortic haemodynamics in order to support clinical decision making. Our approach is multi-scale, using a reduced-order model (1D/0D) and an optimization process for the personalization of patient-specific boundary conditions and aortic vessel wall parameters from non-invasive measurements, to inform a more complex model (3D/0D) representing 3D aortic patient-specific anatomy. The reliability of the modelling approach is investigated by comparing 3D/0D model pressure drop estimation with measured peak gradients recorded during diagnostic cardiac catheterization and 2D PC-MRI flow rate measurements in the descending aorta. The current study demonstrated that the proposed approach requires low levels of user interaction, making it suitable for the clinical setting. The agreement between computed blood pressure drop and catheter measurements is 10  ±  8 mmHg at the coarctation site. The comparison between CFD derived and catheter measured pressure gradients indicated that the model has to be improved, suggesting the use of time varying pressure waveforms to further optimize the tuning process and modelling assumptions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Hidrodinâmica / Modelagem Computacional Específica para o Paciente Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coartação Aórtica / Hidrodinâmica / Modelagem Computacional Específica para o Paciente Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article