Copper ion modified graphitic C3N4 nanosheets enhanced luminol-H2O2 chemiluminescence system: Toward highly selective and sensitive bioassay of H2S in human plasma.
Cao, Jun-Tao; Zhang, Wen-Sheng; Fu, Xiao-Long; Wang, Hui; Ma, Shu-Hui; Liu, Yan-Ming.
Afiliação
  • Cao JT; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, PR China. Electronic address: jtcao11@163.com.
  • Zhang WS; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, PR China; Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzho
  • Fu XL; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, PR China.
  • Wang H; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, PR China.
  • Ma SH; Xinyang Central Hospital, Xinyang 464000, PR China.
  • Liu YM; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, PR China. Electronic address: liuym9518@sina.com.
Spectrochim Acta A Mol Biomol Spectrosc ; 230: 118040, 2020 Apr 05.
Article em En | MEDLINE | ID: mdl-31931354
ABSTRACT
A high-efficient chemiluminescence (CL) platform for highly selective and sensitive H2S detection was constructed on the basis of the quenching effect of S2- on the copper ion modified graphitic carbon nitride nanosheets (Cu2+-g-C3N4 NSs) enhanced luminol-H2O2 system. Cu2+-g-C3N4 NSs with horseradish peroxidase-like catalytic activity were prepared and provide a great improvement for luminol-H2O2 system. The presence of S2- induced the formation of CuS precipitate on g-C3N4 NSs surface. The precipitate can block the catalytic Cu2+ sites on the g-C3N4 NSs surface, resulting in a great CL decrease of CL system. Based on such a mechanism, a simple, highly selective and sensitive CL biosensor for H2S detection was designed. Under the optimized conditions, luminol-H2O2-Cu2+-g-C3N4 NSs system gave a decrease of CL intensity with the Na2S concentration increasing. The CL biosensor is in a linear range of 10.0 pM-50.0 nM and the detection limit for detecting Na2S is as low as 2.0 pM. Moreover, the method here has enjoyed a successful application for determining H2S in human plasma samples and the recovery is between 95.7% and 110.0%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Nitrogênio / Substâncias Luminescentes / Nanoestruturas / Grafite / Sulfeto de Hidrogênio / Luminol Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Nitrogênio / Substâncias Luminescentes / Nanoestruturas / Grafite / Sulfeto de Hidrogênio / Luminol Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2020 Tipo de documento: Article