Your browser doesn't support javascript.
loading
Clinical outcomes after femtosecond laser-assisted implantation of an intrastromal corneal ring segment with a 340-degree arc length in postkeratoplasty patients: 12-month follow-up.
Tzelikis, Patrick F; Jácome, Antônio Helbert G M; Rocha, Guilherme Andrade N; Hida, Wilson Takashi; Barbosa de Souza, Luciene.
Afiliação
  • Tzelikis PF; Department of Ophthalmology, Hospital Oftalmológico de Brasília-HOB, DF, Brazil.
J Cataract Refract Surg ; 46(1): 78-85, 2020 01.
Article em En | MEDLINE | ID: mdl-32050236
ABSTRACT

PURPOSE:

To assess the clinical outcomes after implantation of a new 340-degree arc length intrastromal corneal ring segment (ICRS) aided by the femtosecond laser in postkeratoplasty patients after a 12-month follow-up.

SETTING:

Private practice, Brasilia, Brazil.

DESIGN:

Prospective case series.

METHODS:

Eyes with previous keratoplasty had ICRS implantation assisted by femtosecond laser. The primary outcome measure was the change in the uncorrected distance visual acuity (UDVA) 12 months postoperatively. The secondary outcome measures were the corrected distance visual acuity (CDVA), refraction, and corneal tomography 1, 3, 6, and 12 months postoperatively. The astigmatism results were analyzed using vector analysis through the double-angle polar plot.

RESULTS:

Of the 18 patients, 7 (38.9%) were men, and 11 (61.1%) were women. The mean UDVA was 20/250 (1.15 logarithm of the minimum angle of resolution [logMAR]) before implantation and 20/70 (0.54 logMAR) at the last follow-up (P < .001). The mean CDVA improved from 20/35 (0.26 logMAR) to 20/25 (0.10 logMAR) (P < .001). The mean spherical equivalent and astigmatism components were significantly reduced after ICRS implantation. The mean corneal astigmatism decreased from 5.55 ± 2.29 D preoperatively to 3.92 ± 1.82 D postoperatively (P < .001). The CDVA remained the same or improved in 19 of 20 eyes and decreased by 1 line in 1 patient. There were no surgical complications.

CONCLUSION:

A new ICRS with a 340-degree arc length was effective in treating postkeratoplasty eyes, improving visual acuity and reducing corneal astigmatism.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Ceratoplastia Penetrante / Substância Própria / Implantação de Prótese / Ceratocone Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Ceratoplastia Penetrante / Substância Própria / Implantação de Prótese / Ceratocone Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil