Your browser doesn't support javascript.
loading
Enhanced specificity due to method specific limits for relative ion intensities in a high-performance liquid chromatography - tandem mass spectrometry method for iohexol in human serum.
Schweinsberg, Vincent; Eckelt, Stefan; Schulz, Anna Marta; Arlt, Marcel; Schumann, Marc; van der Giet, Markus; Tauber, Rudolf; Binscheck-Domaß, Torsten; Kießling, Peggy.
Afiliação
  • Schweinsberg V; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Institute for Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Berlin, Germany.
  • Eckelt S; Labor Berlin-Charité Vivantes GmbH, Department of Laboratory Medicine and Toxicology, Sylter Str. 2, 13353 Berlin, Germany.
  • Schulz AM; Labor Berlin-Charité Vivantes GmbH, Department of Laboratory Medicine and Toxicology, Sylter Str. 2, 13353 Berlin, Germany.
  • Arlt M; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nephrology, Berlin, Germany.
  • Schumann M; Labor Berlin-Charité Vivantes GmbH, Department of Laboratory Medicine and Toxicology, Sylter Str. 2, 13353 Berlin, Germany.
  • van der Giet M; Labor Berlin-Charité Vivantes GmbH, Department of Laboratory Medicine and Toxicology, Sylter Str. 2, 13353 Berlin, Germany.
  • Tauber R; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nephrology, Berlin, Germany.
  • Binscheck-Domaß T; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Institute for Laboratory Medicine, Clinical Chemistry and Pathobiochemistry, Berlin, Germany.
  • Kießling P; Labor Berlin-Charité Vivantes GmbH, Department of Laboratory Medicine and Toxicology, Sylter Str. 2, 13353 Berlin, Germany.
Clin Chem Lab Med ; 58(5): 709-718, 2020 04 28.
Article em En | MEDLINE | ID: mdl-32069224

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Alemanha