Feasibility and reliability of DEXA analysis after total ankle arthroplasty: A cadaver study.
Venjakob, Elina; Yao, Daiwei; Ettinger, Sarah; Claassen, Leif; Schwarze, Michael; Plaass, Christian; Stukenborg-Colsman, Christina; Lerch, Matthias.
Afiliação
  • Venjakob E; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Yao D; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Ettinger S; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Claassen L; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Schwarze M; Laboratory for Biomechanics and Biomaterials, Department of Orthopaedics, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625 Hannover, Germany.
  • Plaass C; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Stukenborg-Colsman C; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Lerch M; Department for Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany. Electronic address: matthias.lerch@diakovere.de.
Foot Ankle Surg ; 27(1): 110-115, 2021 Jan.
Article em En | MEDLINE | ID: mdl-32197888
BACKGROUND: Although the outcomes of total ankle arthroplasty (TAA) have improved, unsolved problems such as stress shielding remain. Although dual energy X-ray absorptiometry (DEXA) is the "gold standard" for evaluation of these issues, it is rarely used in patients after TAA. This study aimed to establish a scan technique and to assess the mechanical changes in bone density caused by bone stock preparation. METHODS: Eight fresh-frozen cadaver legs were investigated by DEXA before TAA, with implant in situ, and after implant removal. Scan surface, bone mineral content, and bone mineral density were analysed to assess mechanical bone mass changes. RESULTS: We examined data for density changes by bone compression after TAA, and found "good" results for internal reliability but only "acceptable" results for external reliability. CONCLUSIONS: The results were reliable and reproducible. Using the present data, mechanical and biological processes can be considered together to understand the postoperative phases of bone remodelling after TAA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Absorciometria de Fóton / Densidade Óssea / Artroplastia de Substituição do Tornozelo / Articulação do Tornozelo Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Foot Ankle Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha País de publicação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Absorciometria de Fóton / Densidade Óssea / Artroplastia de Substituição do Tornozelo / Articulação do Tornozelo Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Foot Ankle Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha País de publicação: França