Your browser doesn't support javascript.
loading
Characterization of a microSilicon diode detector for small-field photon beam dosimetry.
Akino, Yuichi; Fujiwara, Masateru; Okamura, Keita; Shiomi, Hiroya; Mizuno, Hirokazu; Isohashi, Fumiaki; Suzuki, Osamu; Seo, Yuji; Tamari, Keisuke; Ogawa, Kazuhiko.
Afiliação
  • Akino Y; Oncology Center, Osaka University Hospital, 2-2 (D10), Yamadaoka, Suita, Osaka 565-0871, Japan.
  • Fujiwara M; Department of Radiation Oncology, Suita Tokushukai Hospital, Suita, Osaka 565-0814, Japan.
  • Okamura K; Department of Radiation Oncology, Suita Tokushukai Hospital, Suita, Osaka 565-0814, Japan.
  • Shiomi H; Department of Radiology, Osaka University Hospital, Suita, Osaka 565-0871, Japan.
  • Mizuno H; Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
  • Isohashi F; Division of Health Sciences, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
  • Suzuki O; Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
  • Seo Y; Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
  • Tamari K; Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
  • Ogawa K; Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan.
J Radiat Res ; 61(3): 410-418, 2020 May 22.
Article em En | MEDLINE | ID: mdl-32211851
ABSTRACT
This study characterized a new unshielded diode detector, the microSilicon (model 60023), for small-field photon beam dosimetry by evaluating the photon beams generated by a TrueBeam STx and a CyberKnife. Temperature dependence was evaluated by irradiating photons and increasing the water temperature from 11.5 to 31.3°C. For Diode E, microSilicon, microDiamond and EDGE detectors, dose linearity, dose rate dependence, energy dependence, percent-depth-dose (PDD), beam profiles and detector output factor (OFdet) were evaluated. The OFdet of the microSilicon detector was compared to the field output factors of the other detectors. The microSilicon exhibited small temperature dependence within 0.4%, although the Diode E showed a linear variation with a ratio of 0.26%/°C. The Diode E and EDGE detectors showed positive correlations between the detector reading and dose rate, whereas the microSilicon showed a stable response within 0.11%. The Diode E and microSilicon demonstrated negative correlations with the beam energy. The OFdet of microSilicon was the smallest among all the detectors. The maximum differences between the OFdet of microSilicon and the field output factors of microDiamond were 2.3 and 1.6% for 5 × 5 mm2 TrueBeam and 5 mm φ CyberKnife beams, respectively. The PDD data exhibited small variations in the dose fall-off region. The microSilicon and microDiamond detectors yielded similar penumbra widths, whereas the other detectors showed steeper penumbra profiles. The microSilicon demonstrated favorable characteristics including small temperature and dose rate dependence as well as the small spatial resolution and output factors suitable for small field dosimetry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Silício / Planejamento da Radioterapia Assistida por Computador / Fótons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: J Radiat Res Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Silício / Planejamento da Radioterapia Assistida por Computador / Fótons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: J Radiat Res Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão