Your browser doesn't support javascript.
loading
Hemolysis tendency of anticancer nanoparticles changes with type of blood group antigen: An insight into blood nanoparticle interactions.
Singh, Nimisha; Sahoo, Suban K; Kumar, Rajender.
Afiliação
  • Singh N; Department of Applied Chemistry, S.V. National Institute of Technology, Surat 395007, Gujarat, India.
  • Sahoo SK; Department of Applied Chemistry, S.V. National Institute of Technology, Surat 395007, Gujarat, India.
  • Kumar R; Department of Applied Chemistry, S.V. National Institute of Technology, Surat 395007, Gujarat, India. Electronic address: rajender@cuhimachal.ac.in.
Mater Sci Eng C Mater Biol Appl ; 109: 110645, 2020 Apr.
Article em En | MEDLINE | ID: mdl-32228982
ABSTRACT
Different blood groups of ABO system have specific antigen which bestows them with different biochemical properties and hence they can show different hemolytic activity. In this report, hemolytic activity of thiol-functionalized Fe3O4-Au nanoparticles were studied in presence and absence of doxorubicin and the effect of various thiol coatings were correlated towards their hemolysis tendency. The nanoparticles were functionalized with four different amino thiols, cysteamine (CEA), cystamine (CA), cysteine (Cys) and cystine (Cyt) to form Fe3O4-Au CEA, Fe3O4-Au CA, Fe3O4-Au Cys and Fe3O4-Au Cyt nanoparticles which were loaded with anticancer drug, doxorubicin. The functionalization was characterized using ATR-FTIR, HR-TEM, XPS and other spectroscopic methods. Maximum drug encapsulation efficiency of 83% was observed with Fe3O4-Au CA nanoparticles. In-vitro experiments were performed on HeLa cells to check the cellular uptake and cytotoxicity using MTT assay. Hemolytic activity was then analyzed with all the blood groups (positive and negative). The amino acid functionalized, Fe3O4-Au Cys and Fe3O4-Au Cyt nanoparticles, shows lesser hemolysis compared to amino thiol functionalized Fe3O4-Au CEA, and Fe3O4-Au CA nanoparticles. In positive blood groups, the Fe3O4-Au CA nanoparticles shows the highest rate of hemolysis followed by Fe3O4-Au CEA, while the lowest hemolysis rate was observed for Fe3O4-Au Cyt nanoparticles. For negative blood groups, the thiol coated nanoparticles show more abrupt hemolysis rate depending upon the type of antigen.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema ABO de Grupos Sanguíneos / Doxorrubicina / Nanocápsulas / Nanopartículas de Magnetita / Hemólise / Antibióticos Antineoplásicos Limite: Humans Idioma: En Revista: Mater Sci Eng C Mater Biol Appl Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sistema ABO de Grupos Sanguíneos / Doxorrubicina / Nanocápsulas / Nanopartículas de Magnetita / Hemólise / Antibióticos Antineoplásicos Limite: Humans Idioma: En Revista: Mater Sci Eng C Mater Biol Appl Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Índia