Your browser doesn't support javascript.
loading
Three-Dimensional Microporous Hollow Fiber Membrane Microfluidic Device Integrated with Selective Separation and Capillary Self-Driven for Point-of-Care Testing.
Wu, Huimin; Ma, Zhen; Wei, Chenjie; Jiang, Min; Hong, Xiao; Li, Yang; Chen, Dajing; Huang, Xiaojun.
Afiliação
  • Wu H; MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Ma Z; School of Medicine, Hangzhou Normal University, Hangzhou 311121, China.
  • Wei C; MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Jiang M; School of Medicine, Hangzhou Normal University, Hangzhou 311121, China.
  • Hong X; MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Li Y; MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Chen D; School of Medicine, Hangzhou Normal University, Hangzhou 311121, China.
  • Huang X; MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Anal Chem ; 92(9): 6358-6365, 2020 05 05.
Article em En | MEDLINE | ID: mdl-32250102
The novel 3D microfluidic concept of "lab-on-hollow fiber membrane (HFM)" was presented for multifunctional and rapid biological assays, integrating sample size sieving and colorimetric quantification in an HFM. Herein, microporous HFMs with a gradient pore size and high hydrophilic flux were used as microfluidic device substrates. The membrane pores selectively trapped macromolecules within the inner surface, while allowing free diffusion of smaller molecules, including glucose and protein. The microfluidic flow rate in HFM closely followed the Lucas-Washburn and Laplace's models, indicating that the microfluidics facilitated the upward flow of the fluid by microcapillary action without external pumping. Subsequently, for sensing of different biomolecules, a highly sensitive fluorescent or optical chromogenic reagent was immobilized in HFM by an electrostatic interaction. Pyronin G fluorescence reagent was quenched by blood glucose, and the quenching efficiency showed a good linear correlation with glucose concentration (1-22 mM, R2 = 0.997). Moreover, this sensing platform was then further applied for the analysis of urine protein or glucose in the visible spectrum, with a wide testing range. Compared to traditional 2D flat membrane devices, this 3D-HFM microfluidic device exhibited excellent sensing versatility and color rendering uniformity with enhanced sensitivity. Target molecules screening, conditioning, enzymatic recognition, and signal readout of biomolecules have all been implemented on this device, which has paved the way to highly sensitive assays on point-of-care testing (POCT).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Dispositivos Lab-On-A-Chip / Testes Imediatos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Dispositivos Lab-On-A-Chip / Testes Imediatos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos