Your browser doesn't support javascript.
loading
Accuracy Improvement of Binocular Vision Measurement System for Slope Deformation Monitoring.
Hu, Qijun; Feng, Ziyuan; He, Leping; Shou, Zihe; Zeng, Junsen; Tan, Jie; Bai, Yu; Cai, Qijie; Gu, Yucheng.
Afiliação
  • Hu Q; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
  • Feng Z; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
  • He L; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
  • Shou Z; Sichuan Tibetan Area Expressway Co., Ltd., Chengdu 610041, China.
  • Zeng J; School of Mechatronic Engineering, Southwest Petroleum University, Chengdu 610500, China.
  • Tan J; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
  • Bai Y; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
  • Cai Q; School of Transportation and Logistics, Southwest Jiaotong University, Chengdu 610031, China.
  • Gu Y; School of Civil Engineering and Geomatics, Southwest Petroleum University, Chengdu 610500, China.
Sensors (Basel) ; 20(7)2020 Apr 02.
Article em En | MEDLINE | ID: mdl-32252476
This paper studies the limitations of binocular vision technology in monitoring accuracy. The factors affecting the surface displacement monitoring of the slope are analyzed mainly from system structure parameters and environment parameters. Based on the error analysis theory, the functional relationship between the structure parameters and the monitoring error is studied. The error distribution curve is obtained through laboratory testing and sensitivity analysis, and parameter selection criteria are proposed. Corresponding image optimization methods are designed according to the error distribution curve of the environment parameters, and a large number of tests proved that the methods effectively improved the measurement accuracy of slope deformation monitoring. Finally, the reliability and accuracy of the proposed system and method are verified by displacement measurement of a slope on site.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China País de publicação: Suíça