Association of bacterial load in drinking water and allergic diseases in childhood.
Clin Exp Allergy
; 50(6): 733-740, 2020 06.
Article
em En
| MEDLINE
| ID: mdl-32270527
BACKGROUND: Treatment of drinking water may decrease microbial exposure. OBJECTIVE: To investigate whether bacterial load in drinking water is associated with altered risk of allergic diseases. METHODS: We recruited 1,110 schoolchildren aged 6-16 years between 2011 and 2013 in Pozega-Slavonia County in Croatia, where we capitalized on a natural experiment whereby individuals receive drinking water through public mains supply or individual wells. We obtained data on microbial content of drinking water for all participants; 585 children were randomly selected for more detailed assessments, including skin prick testing. Since water supply was highly correlated with rural residence, we compared clinical outcomes across four groups (Rural/Individual, Rural/Public, Urban/Individual and Urban/Public). For each child, we derived quantitative index of microbial exposure (bacterial load in the drinking water measured during the child's first year of life). RESULTS: Cumulative bacterial load in drinking water was higher (median [IQR]: 6390 [4190-9550] vs 0 [0-0]; P < .0001), and lifetime prevalence of allergic diseases was significantly lower among children with individual supply (5.5% vs 2.3%, P = .01; 14.4% vs 6.7%, P < .001; 25.2% vs 15.1%, P < .001; asthma, atopic dermatitis [AD] and rhinitis, respectively). Compared with the reference group (Urban/Public), there was a significant reduction in the risk of ever asthma, AD and rhinitis amongst rural children with individual supply: OR [95% CI]: 0.14 [0.03,0.67], P = .013; 0.20 [0.09,0.43], P < .001; 0.17 [0.10,0.32], P < .001. Protection was also observed in the Rural/Public group, but the effect was consistently highest among Rural/Individual children. In the quantitative analysis, the risk of allergic diseases decreased significantly with increasing bacterial load in drinking water in the first year of life (0.79 [0.70,0.88], P < .001; 0.90 [0.83,0.99], P = .025; 0.80 [0.74,0.86], P < .001; current wheeze, AD and rhinitis). CONCLUSIONS AND CLINICAL RELEVANCE: High commensal bacterial content in drinking water may protect against allergic diseases.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Microbiologia da Água
/
Água Potável
/
Carga Bacteriana
/
Hipersensibilidade
Tipo de estudo:
Clinical_trials
/
Risk_factors_studies
Limite:
Adolescent
/
Child
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Clin Exp Allergy
Assunto da revista:
ALERGIA E IMUNOLOGIA
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Croácia
País de publicação:
Reino Unido