Your browser doesn't support javascript.
loading
Combining surface-enhanced Raman scattering (SERS) of saliva and two-dimensional shear wave elastography (2D-SWE) of the parotid glands in the diagnosis of Sjögren's syndrome.
Moisoiu, Vlad; Badarinza, Maria; Stefancu, Andrei; Iancu, Stefania D; Serban, Oana; Leopold, Nicolae; Fodor, Daniela.
Afiliação
  • Moisoiu V; Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania.
  • Badarinza M; 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
  • Stefancu A; Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania; MEDFUTURE Research Center for Advanced Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
  • Iancu SD; Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania.
  • Serban O; 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
  • Leopold N; Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania; MEDFUTURE Research Center for Advanced Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. Electronic address: nicolae.leopold@phys.ubbcluj.ro.
  • Fodor D; 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. Electronic address: dfodor@umfcluj.ro.
Spectrochim Acta A Mol Biomol Spectrosc ; 235: 118267, 2020 Jul 05.
Article em En | MEDLINE | ID: mdl-32276224
ABSTRACT
In this study, we combine the molecular structural information gained by SERS of saliva samples with the morphological data given by two-dimensional shear wave elastography (2D-SWE) (SuperSonic Imagine, Aixplorer) of parotid glands in the case of n = 31 patients with Sjögren's syndrome (SjS) and n = 22 controls, with the aim to discriminate between the two groups. The overall classification accuracy yielded by a hybrid principal component analysis-linear discriminant analysis (PCA-LDA) model based on both SERS and elastography (81%) was superior to that yielded by SERS spectra alone (75%) and elastography data alone (71%). This preliminary study is the first report on the use of 2D-SWE of parotid glands for the diagnosis of SjS as well as the first to describe the diagnosis of SjS based on the SERS spectra of dried saliva samples, the results suggesting that the strategy of combining the two methods could improve the diagnosis of SjS.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândula Parótida / Saliva / Análise Espectral Raman / Síndrome de Sjogren Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Romênia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândula Parótida / Saliva / Análise Espectral Raman / Síndrome de Sjogren Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Romênia