Your browser doesn't support javascript.
loading
Transcatheter aortic root replacement with chimney grafts for coronary perfusion: a preliminary test in a three-dimensional-printed root model.
Ferrari, Enrico; Scoglio, Martin; Piazza, Giulia; Maisano, Francesco; von Segesser, Ludwig Karl; Berdajs, Denis.
Afiliação
  • Ferrari E; Cardiovascular Surgery Unit, Cardiocentro Ticino, Lugano, Switzerland.
  • Scoglio M; Cardiovascular Surgery Unit, University Hospital of Zurich, Zurich, Switzerland.
  • Piazza G; Cardiovascular Research Unit, University Hospital of Lausanne, Lausanne, Switzerland.
  • Maisano F; Cardiovascular Research Unit, University Hospital of Lausanne, Lausanne, Switzerland.
  • von Segesser LK; Cardiovascular Surgery Unit, University Hospital of Zurich, Zurich, Switzerland.
  • Berdajs D; Cardiovascular Research Unit, University Hospital of Lausanne, Lausanne, Switzerland.
Interact Cardiovasc Thorac Surg ; 31(1): 121-128, 2020 07 01.
Article em En | MEDLINE | ID: mdl-32303058
OBJECTIVES: Transcatheter aortic root repair is still not available because of the technical challenge of coronary perfusion. The use of chimney grafts for coronary ostia can be an option and we tested the flow-through coronary chimney grafts deployed in a 3-dimensional-printed root model as part of a transcatheter aortic root repair system. METHODS: A 3-dimensional-printed root was used to test the coronary flow after the deployment of 1 root endograft (28 mm diameter) and two 6-mm diameter 10-cm long coronary chimney grafts. Continuous coronary flows were measured in a bench test at different pressure levels (60, 80 and 100 mmHg) and compared to target coronary flows (250 ml/min at rest for the left and 150 ml/min at rest for the right coronary artery). RESULTS: The computed tomography scan-based root was modified with two 5-mm diameter coronary conduits to overcome the limits of the original 3-dimensional-printed coronary ostia. The root was placed in the hydrodynamic system: adjusted coronary free flow at 60, 80 and 100 mmHg of pressure was 1913, 2200 and 2480 ml/min for left coronary and 1633, 2026 and 2366 ml/min for right coronary, respectively. After endografts deployment, mean chimney graft flow at 60, 80 and 100 mmHg of pressure was 1053 ml/min (-45%), 1306 ml/min (-41%) and 1502 ml/min (-40%) for the left coronary and 1100 ml/min (-33%), 1460 ml/min (-28%) and 1626 ml/min (-31%) for the right coronary, respectively. CONCLUSIONS: In this preliminary study, chimney grafts for transcatheter aortic root repair provided 830% of target flow in the right coronary (-31% of free flow) and 414% of target flow in the left coronary (-42% of free flow) which is more than sufficient for both coronaries in real-life conditions. The potential of this approach should be further explored with specifically designed endografts.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Transposição dos Grandes Vasos / Circulação Coronária / Vasos Coronários / Implante de Prótese Vascular / Procedimentos Endovasculares / Transposição das Grandes Artérias Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: En Revista: Interact Cardiovasc Thorac Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Suíça País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Transposição dos Grandes Vasos / Circulação Coronária / Vasos Coronários / Implante de Prótese Vascular / Procedimentos Endovasculares / Transposição das Grandes Artérias Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male Idioma: En Revista: Interact Cardiovasc Thorac Surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Suíça País de publicação: Reino Unido