Your browser doesn't support javascript.
loading
Overcoming challenges of the human spinal cord tractography for routine clinical use: a review.
Dauleac, Corentin; Frindel, Carole; Mertens, Patrick; Jacquesson, Timothée; Cotton, François.
Afiliação
  • Dauleac C; Service de Neurochirurgie, Hôpital neurologique et neurochirurgical Pierre Wertheimer, Hospices Civils de Lyon, 59 Bd Pinel, 69003, Lyon, France. corentin.dauleac@chu-lyon.fr.
  • Frindel C; Laboratoire CREATIS, CNRS UMR5220, Inserm U1206, INSA-Lyon, Université de Lyon I, Lyon, France. corentin.dauleac@chu-lyon.fr.
  • Mertens P; Laboratoire CREATIS, CNRS UMR5220, Inserm U1206, INSA-Lyon, Université de Lyon I, Lyon, France.
  • Jacquesson T; Service de Neurochirurgie, Hôpital neurologique et neurochirurgical Pierre Wertheimer, Hospices Civils de Lyon, 59 Bd Pinel, 69003, Lyon, France.
  • Cotton F; Laboratoire d'Anatomie, Université Claude Bernard Lyon I, Lyon, France.
Neuroradiology ; 62(9): 1079-1094, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32363485
ABSTRACT
The spinal cord (SC) is a dense network of billions of fibers in a small volume surrounded by bones that makes tractography difficult to perform. We aim to provide a review collecting all technical settings of SC tractography and propose the optimal set of parameters to perform a good SC tractography rendering. The MEDLINE database was searched for articles reporting "spinal cord" "tractography" in "humans". Studies were selected only when tractography rendering was displayed and MRI acquisition and tracking parameters detailed. From each study, clinical context, imaging acquisition settings, fiber tracking parameters, region of interest (ROI) design, and quality of the tractography rendering were extracted. Quality of tractography rendering was evaluated by several objective criteria proposed herein. According to the reported studies, to obtain a good tractography rendering, diffusion tensor imaging acquisition should be performed with 1.5 or 3 Tesla MRI, in the axial plane, with > 20 directions; b value 1000 s mm-2; right-left phase-encoding direction for cervical SC; isotropic voxel size; and no slice gap. Concerning the tracking process, it should be performed with determinist approach, fractional anisotropy threshold between 0.15 and 0.2, and curvature threshold of 40°. ROI design is an essential step for providing good tractography rendering, and their placement has to consider partial volume effects, magnetic susceptibility effects, and motion artifacts. The review reported herein highlights that successful SC tractography depends on many factors (imaging acquisition settings, fiber tracking parameters, and ROI design) to obtain a good SC tractography rendering.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Espinal / Doenças da Medula Espinal / Imagem de Tensor de Difusão Limite: Humans Idioma: En Revista: Neuroradiology Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Espinal / Doenças da Medula Espinal / Imagem de Tensor de Difusão Limite: Humans Idioma: En Revista: Neuroradiology Ano de publicação: 2020 Tipo de documento: Article País de afiliação: França
...