Your browser doesn't support javascript.
loading
Cardiac MRI for Patients With Cardiac Implantable Electronic Devices.
Stojanovska, Jadranka; Runge, Mason; Mahani, Maryam Ghadimi; Cronin, Paul P; Sayyouh, Mohamed; Bogun, Frank; Ibrahim, El-Sayed H.
Afiliação
  • Stojanovska J; Department of Radiology, Michigan Medicine, University of Michigan, 1500 E Medical Center Dr, Rm 5481, Ann Arbor, MI 48109-5868.
  • Runge M; University of Michigan Medical School, Ann Arbor, MI.
  • Mahani MG; Department of Radiology, C. S. Mott Children's Hospital, Michigan Medicine, University of Michigan, Ann Arbor, MI.
  • Cronin PP; Department of Radiology, Michigan Medicine, University of Michigan, 1500 E Medical Center Dr, Rm 5481, Ann Arbor, MI 48109-5868.
  • Sayyouh M; Department of Radiology, Michigan Medicine, University of Michigan, 1500 E Medical Center Dr, Rm 5481, Ann Arbor, MI 48109-5868.
  • Bogun F; Cardiovascular Center, Michigan Medicine, University of Michigan, Ann Arbor, MI.
  • Ibrahim EH; Department of Radiology, Medical College of Wisconsin, Milwaukee, WI.
AJR Am J Roentgenol ; 215(2): 374-381, 2020 08.
Article em En | MEDLINE | ID: mdl-32374663
ABSTRACT
OBJECTIVE. Patients with cardiac implantable electronic devices (CIEDs) require cardiac MRI (CMRI) for a variety of reasons. The purpose of this study is to review and evaluate the value and safety of CMRI for patients with in situ CIEDs. CONCLUSION. Late gadolinium enhancement CMRI is the reference standard for assessing myocardial viability in patients with ventricular tachycardia before ablation of arrhythmogenic substrates. The use of late gadolinium enhancement CMRI for patients with CIEDs is safe as long as an imaging protocol is in place and precaution measures are taken.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Taquicardia Ventricular / Desfibriladores Implantáveis / Meios de Contraste / Técnicas de Imagem Cardíaca / Gadolínio / Coração Limite: Aged / Female / Humans Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Taquicardia Ventricular / Desfibriladores Implantáveis / Meios de Contraste / Técnicas de Imagem Cardíaca / Gadolínio / Coração Limite: Aged / Female / Humans Idioma: En Revista: AJR Am J Roentgenol Ano de publicação: 2020 Tipo de documento: Article