Your browser doesn't support javascript.
loading
Rosette Trajectories Enable Ungated, Motion-Robust, Simultaneous Cardiac and Liver T2 * Iron Assessment.
Bush, Adam M; Sandino, Christopher M; Ramachandran, Shreya; Ong, Frank; Dwork, Nicholas; Zucker, Evan J; Syed, Ali B; Pauly, John M; Alley, Marcus T; Vasanawala, Shreyas S.
Afiliação
  • Bush AM; Department of Radiology, Stanford University, Palo Alto, California, USA.
  • Sandino CM; Department of Electrical Engineering, Stanford University, Palo Alto, California, USA.
  • Ramachandran S; Department of Electrical Engineering and Computer Science, University of California, Berkeley, California, USA.
  • Ong F; Department of Radiology, Stanford University, Palo Alto, California, USA.
  • Dwork N; Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
  • Zucker EJ; Department of Radiology, Stanford University, Palo Alto, California, USA.
  • Syed AB; Department of Radiology, Stanford University, Palo Alto, California, USA.
  • Pauly JM; Department of Electrical Engineering, Stanford University, Palo Alto, California, USA.
  • Alley MT; Department of Radiology, Stanford University, Palo Alto, California, USA.
  • Vasanawala SS; Department of Radiology, Stanford University, Palo Alto, California, USA.
J Magn Reson Imaging ; 52(6): 1688-1698, 2020 12.
Article em En | MEDLINE | ID: mdl-32452088
BACKGROUND: Quantitative T2 * MRI is the standard of care for the assessment of iron overload. However, patient motion corrupts T2 * estimates. PURPOSE: To develop and evaluate a motion-robust, simultaneous cardiac and liver T2 * imaging approach using non-Cartesian, rosette sampling and a model-based reconstruction as compared to clinical-standard Cartesian MRI. STUDY TYPE: Prospective. PHANTOM/POPULATION: Six ferumoxytol-containing phantoms (26-288 µg/mL). Eight healthy subjects and 18 patients referred for clinically indicated iron overload assessment. FIELD STRENGTH/SEQUENCE: 1.5T, 2D Cartesian and rosette gradient echo (GRE) ASSESSMENT: GRE T2 * values were validated in ferumoxytol phantoms. In healthy subjects, test-retest and spatial coefficient of variation (CoV) analysis was performed during three breathing conditions. Cartesian and rosette T2 * were compared using correlation and Bland-Altman analysis. Images were rated by three experienced radiologists on a 5-point scale. STATISTICAL TESTS: Linear regression, analysis of variance (ANOVA), and paired Student's t-testing were used to compare reproducibility and variability metrics in Cartesian and rosette scans. The Wilcoxon rank test was used to assess reader score comparisons and reader reliability was measured using intraclass correlation analysis. RESULTS: Rosette R2* (1/T2 *) was linearly correlated with ferumoxytol concentration (r2 = 1.00) and not significantly different than Cartesian values (P = 0.16). During breath-holding, ungated rosette liver and heart T2 * had lower spatial CoV (liver: 18.4 ± 9.3% Cartesian, 8.8% ± 3.4% rosette, P = 0.02, heart: 37.7% ± 14.3% Cartesian, 13.4% ± 1.7% rosette, P = 0.001) and higher-quality scores (liver: 3.3 [3.0-3.6] Cartesian, 4.7 [4.1-4.9] rosette, P = 0.005, heart: 3.0 [2.3-3] Cartesian, 4.5 [3.8-5.0] rosette, P = 0.005) compared to Cartesian values. During free-breathing and failed breath-holding, Cartesian images had very poor to average image quality with significant artifacts, whereas rosette remained very good, with minimal artifacts (P = 0.001). DATA CONCLUSION: Rosette k-sampling with a model-based reconstruction offers a clinically useful motion-robust T2 * mapping approach for iron quantification. J. MAGN. RESON. IMAGING 2020;52:1688-1698.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Óxido Ferroso-Férrico / Coração / Fígado Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Óxido Ferroso-Férrico / Coração / Fígado Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos