Your browser doesn't support javascript.
loading
Alignment and Photopolymerization of Hexa-peri-hexabenzocoronene Derivatives Carrying Diacetylenic Side Chains for Charge-Transporting Application.
Lin, Fang-Ju; Yang, Chih-Wen; Chen, Hsiu-Hui; Tao, Yu-Tai.
Afiliação
  • Lin FJ; Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan.
  • Yang CW; Institute of Physics, Academia Sinica, Taipei 115, Taiwan.
  • Chen HH; Department of Molecular Science and Engineering, National Taipei University of Technology, Taipei 106, Taiwan.
  • Tao YT; Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan.
J Am Chem Soc ; 142(27): 11763-11771, 2020 Jul 08.
Article em En | MEDLINE | ID: mdl-32510215
ABSTRACT
Thin films of four discotic liquid-crystalline hexa-peri-hexabenzocoronene (HBC) derivatives carrying three diacetylenic side chains and three saturated alkyl chains at different positions around the central HBC core were prepared on phenyltrichlorosilane-modified SiO2 substrate by the Chinese brush-coating method. The brush-coated films of molecules with D3h symmetry and C1 symmetry all exhibited anisotropic alignment with an edge-on orientation and molecular π-π stacking along the coating direction on the surface, in contrast to the spin-coated films, where a mixture of face-on and edge-on orientations was obtained. Hexagonally packed columnar structure or lamella-like columnar structure was obtained, depending on the location of the diacetylenic unit along the chain. UV irradiation of the films resulted in cross-linking/polymerization of the molecular columns. Among them, the lamella-like structure with a diacetylene unit closer to the HBC core gave more closely packed and ordered HBC arrays with the poly(ene-yne) backbones stretching along the column direction, based on a variety of experimental evidence. A thin-film transistor based on this irradiated film gave a highest mobility of 1.5 cm2 V-1 s-1 along the column direction, which is a 3 orders of magnitude improvement over that of the monomeric film. However, for those with a diacetylenic unit extended farther away from the core, cross-linking between neighboring columns was suggested to occur and no mobility can be measured for devices based on those films.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Chem Soc Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Chem Soc Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan