Your browser doesn't support javascript.
loading
Validation of T2 -based oxygen extraction fraction measurement with 15 O positron emission tomography.
Jiang, Dengrong; Deng, Shengwen; Franklin, Crystal G; O'Boyle, Michael; Zhang, Wei; Heyl, Betty L; Pan, Li; Jerabek, Paul A; Fox, Peter T; Lu, Hanzhang.
Afiliação
  • Jiang D; The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
  • Deng S; Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
  • Franklin CG; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • O'Boyle M; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • Zhang W; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • Heyl BL; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • Pan L; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • Jerabek PA; Siemens Healthineers, Baltimore, MD, USA.
  • Fox PT; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
  • Lu H; Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.
Magn Reson Med ; 85(1): 290-297, 2021 01.
Article em En | MEDLINE | ID: mdl-32643207
ABSTRACT

PURPOSE:

To evaluate the accuracy of T2 -based whole-brain oxygen extraction fraction (OEF) estimation by comparing it with gold standard 15 O-PET measurements.

METHODS:

Sixteen healthy adult subjects underwent MRI and 15 O-PET OEF measurements on the same day. On MRI, whole-brain OEF was quantified by T2 -relaxation-under-spin-tagging (TRUST) MRI, based on subject-specific hematocrit. The TRUST OEF was compared to the whole-brain averaged OEF produced by 15 O-PET. Agreement between TRUST and 15 O-PET whole-brain OEF measurements was examined in terms of intraclass correlation coefficient (ICC) and in absolute OEF values. In a subset of 10 subjects, test-retest reproducibility of whole-brain OEF was also evaluated and compared between the two modalities.

RESULTS:

Across the 16 subjects, the mean whole-brain OEF of TRUST and 15 O-PET were 36.44 ± 4.07% and 36.45 ± 3.65%, respectively, showing no difference between the two modalities (P = .99). TRUST whole-brain OEF strongly correlated with that of 15 O-PET (N = 16, ICC = 0.90, P = 4 × 10-7 ). The coefficient-of-variation of TRUST and 15 O-PET whole-brain OEF measurements were 1.79 ± 0.67% and 2.06 ± 1.55%, respectively, showing no difference between the two modalities (N = 10, P = .64). Further analyses on the effect of hematocrit revealed that correlation between PET OEF and TRUST OEF with assumed hematocrit remained significant (ICC = 0.8, P < 2 × 10-5 ).

CONCLUSION:

Whole-brain OEF measured by TRUST was in excellent agreement with gold standard 15 O-PET, with highly comparable accuracy and reproducibility. These findings suggest that TRUST MRI can provide accurate quantification of whole-brain OEF noninvasively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Circulação Cerebrovascular / Tomografia por Emissão de Pósitrons Limite: Adult / Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Circulação Cerebrovascular / Tomografia por Emissão de Pósitrons Limite: Adult / Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos