Your browser doesn't support javascript.
loading
Interleaved Array Transducer with Polarization Inversion Technique to Implement Ultrasound Tissue Harmonic Imaging.
Park, Chan Yuk; Sung, Jin Ho; Jeong, Eun Young; Lee, Hee Su; Jeong, Jong Seob.
Afiliação
  • Park CY; Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea.
  • Sung JH; Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea.
  • Jeong EY; Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea.
  • Lee HS; Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea.
  • Jeong JS; Department of Medical Biotechnology, Dongguk University, Seoul 04620, Korea.
Sensors (Basel) ; 20(14)2020 Jul 14.
Article em En | MEDLINE | ID: mdl-32674455
ABSTRACT
In ultrasound tissue harmonic imaging (THI), it is preferred that the bandwidth of the array transducer covers at least the fundamental frequency f0 for transmission and the second harmonic frequency 2f0 for reception. However, it is challenging to develop an array transducer with a broad bandwidth due to the single resonance characteristics of piezoelectric materials. In this study, we present an improved interleaved array transducer suitable for THI and a dedicated transducer fabrication scheme. The proposed array transducer has a novel structure in which conventional elements exhibiting f0 resonant frequency and polarization-inverted elements exhibiting 2f0 resonant frequency are alternately located, and the thicknesses of all piezoelectric elements are identical. The performance of the proposed method was demonstrated by finite element analysis (FEA) simulations and experiments using a fabricated prototype array transducer. Using the proposed technique, f0 and 2f0 frequency ultrasounds can be efficiently transmitted and received, respectively, resulting in a 90% broad bandwidth feature of the transducer. Thus, the proposed technique can be one of the potential ways to implement high resolution THI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transdutores / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2020 Tipo de documento: Article