Post-processing of computed tomography perfusion in patients with acute cerebral ischemia: variability of inter-reader, inter-region of interest, inter-input model, and inter-software.
Chen, Zhong-Ping; Shi, Zhen-Zhen; Li, Yun-Geng; Guo, Yan; Tong, Dan.
Afiliação
  • Chen ZP; Department of Radiology, The First Hospital of Jilin University, Changchun, 130021, Jilin, China.
  • Shi ZZ; Department of Radiology, The First Hospital of Jilin University, Changchun, 130021, Jilin, China.
  • Li YG; Department of Radiology, The First Hospital of Jilin University, Changchun, 130021, Jilin, China.
  • Guo Y; Life Sciences, GE Healthcare, Shenyang, 110000, China.
  • Tong D; Department of Radiology, The First Hospital of Jilin University, Changchun, 130021, Jilin, China. tongdan2012@126.com.
Eur Radiol ; 30(12): 6561-6569, 2020 12.
Article em En | MEDLINE | ID: mdl-32683549
ABSTRACT

OBJECTIVE:

To determine the reproducibility of quantitative computed tomography perfusion (CTP) parameters generated using different post-processing methods and identify the relative impact of subjective factors on the robustness of CTP parameters in acute ischemic stroke (AIS). MATERIALS AND

METHODS:

A total of 80 CTP datasets from patients with AIS or transient ischemic attack (TIA) were retrospectively post-processed by two observers using different regions of interest (ROI) types, input models, and software. The CTP parameters were derived for 10 parenchymal ROIs. The intra-class correlation coefficients (ICCs) were used to assess the reproducibility of the CTP parameters for various post-processing methods. The Spearman correlation test was used to detect potential relationships between software and input models.

RESULTS:

The ICCs with 95% confidence intervals (CIs) were 0.94 (0.93-0.96), 0.94 (0.92-0.96), 0.82 (0.79-0.86), and 0.87 (0.85-0.90) for inter-reader agreement by using elliptic ROI, irregular ROI, single-input model, and dual-input model, respectively. The ICCs with 95% CI were 0.98 (0.98-0.98), 0.46 (0.43-0.50), and 0.25 (0.20-0.30) for inter-ROI type, inter-input model, and inter-software agreement, respectively.

CONCLUSIONS:

Although the CTP parameters were stable when measured using different readers with different ROI types, they varied for different input models and software. The standardization of CTP post-processing is essential to reduce variability of CTP values. KEY POINTS • The CTP parameters derived by different readers with different ROI types have agreements that range from good to excellent. • The CTP parameters derived from different input models and software programs have poor agreement but significant correlations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Tomografia Computadorizada por Raios X / Isquemia Encefálica / Circulação Cerebrovascular / Imagem de Perfusão Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Tomografia Computadorizada por Raios X / Isquemia Encefálica / Circulação Cerebrovascular / Imagem de Perfusão Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China