Your browser doesn't support javascript.
loading
Diameter Changes in Traumatic Aortic Injury: Implications for Stent-Graft Sizing.
Berger, Tim; Voetsch, Andreas; Alaloh, Diaa; Kreibich, Maximilian; Krombholz-Reindl, Philipp; Winkler, Andreas; Rylski, Bartosz; Wolfgruber, Thomas; Beyersdorf, Friedhelm; Siepe, Matthias; Seitelberger, Rainald; Czerny, Martin; Gottardi, Roman.
Afiliação
  • Berger T; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Voetsch A; Department of Cardiovascular and Endovascular Surgery, Paraclesus Medical University Salzburg, Salzburg, Austria.
  • Alaloh D; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Kreibich M; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Krombholz-Reindl P; Department of Cardiovascular and Endovascular Surgery, Paraclesus Medical University Salzburg, Salzburg, Austria.
  • Winkler A; Department of Cardiovascular and Endovascular Surgery, Paraclesus Medical University Salzburg, Salzburg, Austria.
  • Rylski B; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Wolfgruber T; Universit Institute for Radiology, Paraclesus Medical University Salzburg, Salzburg, Austria.
  • Beyersdorf F; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Siepe M; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Seitelberger R; Department of Cardiovascular and Endovascular Surgery, Paraclesus Medical University Salzburg, Salzburg, Austria.
  • Czerny M; Department of Cardiovascular Surgery, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Baden Württemberg, Germany.
  • Gottardi R; Department of Cardiovascular and Endovascular Surgery, Paraclesus Medical University Salzburg, Salzburg, Austria.
Thorac Cardiovasc Surg ; 70(4): 333-338, 2022 06.
Article em En | MEDLINE | ID: mdl-32725612
OBJECTIVES: The aim of this study was to compare aortic diameters from admission computed tomography angiography (CTA) scans to postoperative aortic diameters in patients with traumatic aortic injury (TAI) and evaluate the influence of substantial blood loss on aortic diameter. METHODS: The aortic databases of two tertiary university centers were retrospectively screened for patients with TAI between February 2002 and February 2019. Concomitant organ injuries, bone fractures, blood loss, and clinical outcomes were evaluated. Aortic diameters were measured in CTA upon admission and were compared with the CTA before discharge at three different aortic levels (mid-ascending, 5 cm distal to the end of the stent graft, and at the celiac trunk level). RESULTS: We identified 45 patients, aged 43 (first quartile; third quartile [26; 55]) years with a TAI treated by thoracic endovascular aortic repair. The most frequent cause of TAI was a car accident (n = 24). Concomitant injuries were seen in all but one patient. Bone and pelvic fractures were seen in 40 (89%) and 15 (33%) patients, respectively. Type III aortic injury was present in 25 patients (56%). Increase of aortic diameter after stabilization was +1.7 mm (-0.6 mm; 2.5 mm; p = 0.004) at the mid-ascending aorta, +2.1 mm (0.2 mm; 3.8 mm; p < 0.001) 5 cm distal to the stent graft, and +1.5 mm (0.5 mm; 3.2 mm; p < 0.001) at the celiac trunk level. CONCLUSION: In patients with TAI, the aortic diameter is significantly reduced as compared with the aortic diameter at discharge. The reduction of aortic diameter might be caused by hemorrhagic shock and should be kept in mind for appropriate stent-graft sizing.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implante de Prótese Vascular / Lesões do Sistema Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implante de Prótese Vascular / Lesões do Sistema Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Alemanha