Your browser doesn't support javascript.
loading
Implant-forming polymeric 19F MRI-tracer with tunable dissolution.
Kolouchova, Kristyna; Jirak, Daniel; Groborz, Ondrej; Sedlacek, Ondrej; Ziolkowska, Natalia; Vit, Martin; Sticova, Eva; Galisova, Andrea; Svec, Pavel; Trousil, Jiri; Hajek, Milan; Hruby, Martin.
Afiliação
  • Kolouchova K; Institute of Macromolecular Chemistry CAS, Heyrovsky Square 2, 162 06 Prague 6, Czech Republic; Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, Prague 2 128 00, Czech Republic.
  • Jirak D; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic; Department of Science and Research, Faculty of Health Studies, Technical University of Liberec, Studentska 1402/2, 461 17 Liberec, Czech Republic
  • Groborz O; Institute of Macromolecular Chemistry CAS, Heyrovsky Square 2, 162 06 Prague 6, Czech Republic; Department of Organic Chemistry, Charles University, Faculty of Science, Hlavova 8, 128 43 Prague 2, Czech Republic; Institute of Biophysics and Informatics, Charles University, First Faculty of Medicine,
  • Sedlacek O; Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, 9000 Ghent, Belgium.
  • Ziolkowska N; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic; Institute of Biophysics and Informatics, Charles University, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2, Czech Republic.
  • Vit M; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic; Technical University of Liberec, Faculty of Mechatronics Informatics and Interdisciplinary Studies, Studentska 1402/2, 461 17 Liberec, Czech Repu
  • Sticova E; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.
  • Galisova A; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.
  • Svec P; Institute of Macromolecular Chemistry CAS, Heyrovsky Square 2, 162 06 Prague 6, Czech Republic; Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, Prague 2 128 00, Czech Republic.
  • Trousil J; Institute of Macromolecular Chemistry CAS, Heyrovsky Square 2, 162 06 Prague 6, Czech Republic.
  • Hajek M; Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.
  • Hruby M; Institute of Macromolecular Chemistry CAS, Heyrovsky Square 2, 162 06 Prague 6, Czech Republic. Electronic address: mhruby@centrum.cz.
J Control Release ; 327: 50-60, 2020 11 10.
Article em En | MEDLINE | ID: mdl-32730953
Magnetic resonance imaging (MRI) using 19F-based tracers has emerged as a promising multi-purpose noninvasive diagnostic tool and its application requires the use of various 19F-based tracers for the intended diagnostic purpose. In this study, we report a series of double-stimuli-responsive polymers for use as injectable implants, which were designed to form implants under physiological conditions, and to subsequently dissolve with different dissolution rates (t1/2 ranges from 30 to more than 250 days). Our polymers contain a high concentration of fluorine atoms, providing remarkable signal detectability, and both a hydrophilic monomer and a pH-responsive monomer that alter the biodistribution properties of the implant. The implant location and dissolution were observed using 19F MRI, which allows the anatomic extent of the implant to be monitored. The dissolution kinetics and biocompatibility of these materials were thoroughly analyzed. No sign of toxicity in vitro or in vivo or pathology in vivo was observed, even in chronic administration. The clinical applicability of our polymers was further confirmed via imaging of a rat model by employing an instrument currently used in human medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Imageamento por Ressonância Magnética Limite: Animals Idioma: En Revista: J Control Release Assunto da revista: FARMACOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: República Tcheca País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Imageamento por Ressonância Magnética Limite: Animals Idioma: En Revista: J Control Release Assunto da revista: FARMACOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: República Tcheca País de publicação: Holanda