Your browser doesn't support javascript.
loading
Multi-Sample Preparation Assay for Isolation of Nucleic Acids Using Bio-Silica with Syringe Filters.
Noh, Geun Su; Liu, Huifang; Kim, Myoung Gyu; Qiao, Zhen; Jang, Yoon Ok; Shin, Yong.
Afiliação
  • Noh GS; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
  • Liu H; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
  • Kim MG; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
  • Qiao Z; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
  • Jang YO; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
  • Shin Y; Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology (AMIST), University of Ulsan College of Medicine, 88 Olympicro-43gil, Songpa-gu, Seoul 05505, Korea.
Micromachines (Basel) ; 11(9)2020 Aug 30.
Article em En | MEDLINE | ID: mdl-32872601
The spin-column system for the isolation of nucleic acids (NAs) from multiple samples presents the inconvenience of repeated experimentation, time-consumption, and the risk of contamination in the process of the spin-column exchange. Herein, we propose a convenient and universal assay that can be used to diagnose multiple pathogens using a multi-sample preparation assay. The multi-sample preparation assay combines a 96-well filter/membrane plate, a bio-micromaterial lattice-like micro amine-functional diatomaceous earth (D-APDMS), and homobifunctional imidoesters (HI) for the processing of pathogen enrichment and extraction for multiple samples simultaneously. The purity and quantity of the extracted NAs from pathogens (E. coli and Brucella) using the proposed assay is superior to that of the commercialized spin-column kit. The assay also does not require the replacement of several collection tubes during the reaction processing. For the multi-sample testing, we used as many as six samples simultaneously with the proposed assay. This assay can simultaneously separate up to 96 NAs from one plate, and the use of multichannel pipettes allows faster and simpler experimentation. Therefore, we believe it is a convenient and easy process, and can be easily integrated with other detection methods for clinical diagnostics.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2020 Tipo de documento: Article País de publicação: Suíça