Your browser doesn't support javascript.
loading
Von Mises stresses on Mushroom-loop archwires for incisor retraction: a numerical study.
Ferreira, Marcelo do Amaral; Rodrigues, Fábio Rodrigo Mandello; Luersen, Marco Antônio; Borges, Paulo César; Nanda, Ravindra; Almeida, Marcio Rodrigues de.
Afiliação
  • Ferreira MDA; Private Practice (Curitiba/PR, Brazil).
  • Rodrigues FRM; Universidade Tecnológica Federal do Paraná, Departamento Acadêmico de Mecânica (Curitiba and Pato Branco/PR, Brazil).
  • Luersen MA; Universidade Tecnológica Federal do Paraná, Departamento Acadêmico de Mecânica (Curitiba and Pato Branco/PR, Brazil).
  • Borges PC; Universidade Tecnológica Federal do Paraná, Departamento Acadêmico de Mecânica (Curitiba and Pato Branco/PR, Brazil).
  • Nanda R; University of Connecticut, Department of Craniofacial Sciences (Farmington/CT, USA).
  • Almeida MR; Universidade Norte do Paraná, Departamento de Ortodontia (Londrina/PR, Brazil).
Dental Press J Orthod ; 25(4): 44-50, 2020.
Article em En | MEDLINE | ID: mdl-32965386
ABSTRACT

OBJECTIVE:

To perform a numerical simulation using FEM to study the von Mises stresses on Mushroom archwires.

METHODS:

Mushroom archwires made of titanium-molybdenum alloy with 0.017 x 0.025-in cross-section were used in this study. A YS of 1240 MPa and a Young's modulus of 69 GPa were adopted. The archwire was modeled in Autodesk Inventor software and its behavior was simulated using the finite element code Ansys Workbench (Swanson Analysis Systems, Houston, Pennsylvania, USA). A large displacement simulation was used for non-linear analysis. The archwires were deformed in their extremities with 0° and 45°, and activated by their vertical extremities separated at 4.0 or 5.0 mm.

RESULTS:

Tensions revealed a maximum of 1158 MPa at the whole part of the loop at 5.0mm of activation, except in a very small area situated at the top of the loop, in which a maximum of 1324 Mpa was found.

CONCLUSIONS:

Mushroom loops are capable to produce tension levels in an elastic range and could be safely activated up to 5.0mm.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agaricales / Incisivo Idioma: En Revista: Dental Press J Orthod Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agaricales / Incisivo Idioma: En Revista: Dental Press J Orthod Ano de publicação: 2020 Tipo de documento: Article
...