Your browser doesn't support javascript.
loading
Evaluation of Root-End Preparation with Two Different Endodontic Microsurgery Ultrasonic Tips.
Palma, Paulo J; Marques, Joana A; Casau, Margarida; Santos, André; Caramelo, Francisco; Falacho, Rui I; Santos, João Miguel.
Afiliação
  • Palma PJ; Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
  • Marques JA; Center for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
  • Casau M; Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
  • Santos A; Dentistry Department, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
  • Caramelo F; Dentistry Department, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
  • Falacho RI; Coimbra Institute for Clinical and Biomedical Research (iCBR), Laboratory of Biostatistics and Medical Informatics (LBIM), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal.
  • Santos JM; Institute of Oral Implantology and Prosthodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal.
Biomedicines ; 8(10)2020 Sep 28.
Article em En | MEDLINE | ID: mdl-32998221
ABSTRACT
The aim of this study is to compare root-end preparation performed with two different ultrasonic tips-CVDentus and NSK-and respective time requirements. After root-end resection, 32 teeth were randomly divided in two groups, according to the ultrasonic tip used for root-end preparation. Preparation time was recorded. Photomicrographs were taken to assess the following parameters root surface microcracking, marginal integrity and presence of debris. One ultrasonic tip from each group was analyzed through scanning electron microscopy before and after root-end preparation. The significance level was set at α = 0.05. Incidence of microcracks in both groups was 12.5%. Solely intracanal microcracking was found, consistently positioned within the widest side of the remaining dentine. No statistically significant differences were verified between both experimental groups regarding marginal integrity (p = 0.102) and preparation time (p = 0.780), whereas statistical differences (p = 0.003) were found concerning the presence of debris (the minimum registered score was mostly verified in CVDentus group). NSK tips showed major morphological changes, with extensive surface wear and noticeable loss of particles, which was not verified on CVDentus tips. Our findings suggest significant differences regarding root-end preparation walls quality, with CVDentus tips showing better results. Concerning microcracking, as well as preparation time and marginal integrity, both ultrasonic tips showed similar results. Qualitative analysis exposed NSK tips major morphological changes and wear after use, which was not verified on CVDentus tips.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Biomedicines Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Revista: Biomedicines Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Portugal