Your browser doesn't support javascript.
loading
A simple solution to recycle and reuse dental CAD/CAM zirconia block from its waste residuals.
Ding, Hao; Tsoi, James Kit-Hon; Kan, Chi-Wai; Matinlinna, Jukka P.
Afiliação
  • Ding H; Dental Materials Science, Discipline of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR.
  • Tsoi JK; Dental Materials Science, Discipline of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR.
  • Kan CW; Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong SAR.
  • Matinlinna JP; Dental Materials Science, Discipline of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR.
J Prosthodont Res ; 65(3): 311-320, 2021 Aug 21.
Article em En | MEDLINE | ID: mdl-33028797
ABSTRACT
Purpose To seek a simple solution that can recycle and regenerate dental CAD/CAM zirconia green blanks from its waste residuals.Methods Waste residuals (3M® Lava™ Plus HT) were pulverized after dry milling and cutting, and subsequently sieved before pickling in a 0.5 M nitric acid. These powders were then dry-pressed and pre-sintered into blocks at seven different temperatures in the range 800-1100 °C. New zirconia blocks flagged with the same batch numbers were used as control. These blocks were cut into bars before subjected them to manufacturer-recommended sintering at 1450 °C. Crystalline phases (by XRD), elemental compositions (by EDX), surface morphologies (by SEM), machinability, linear shrinkage rate, relative density, and Knoop microhardness were evaluated before and after sintering, and four-point flexural strengths were also evaluated for the sintered zirconia bars.Results Only tetragonal phases were found in both pre- and fully-sintered recycled zirconia blocks. SEM results showed that pre-sintered samples at 950 °C had smooth and flat surfaces with evenly distributed particles. Recycled and control zirconia blocks had similar elemental compositions. Results from machined surface, linear shrinkage rate, relative density, and Knoop microhardness established that 950 °C and 1000 °C were suitable pre-sintering temperatures for recycling zirconia. Pre-sintered recycled zirconia had no significant differences in flexural strengths, however, samples pre-sintered at 1000 °C exhibited the closest value (897 MPa) compared to that of the control (904 MPa).Conclusions Dental CAD/CAM zirconia can be recycled and reused from its waste residuals by adopting a simple method that requires a pre-sintering at 950 or 1000 °C.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cerâmica / Materiais Dentários Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de publicação: JAPAN / JAPON / JAPÃO / JP

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cerâmica / Materiais Dentários Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de publicação: JAPAN / JAPON / JAPÃO / JP